Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Thermal lensing during infrared neural stimulation enables spatially resolved photothermal dosimetry

  • Jacob Hardenburger
  • , Bryan Millis
  • , Joel Bixler
  • , Christopher Valdez
  • , E. Duco Jansen
  • , Anita Mahadevan-Jansen

Producción científica: Articlerevisión exhaustiva

Resumen

Photothermal laser tissue interactions are challenging to study at the subcellular level due to the complexity of accurately characterizing spatial energy distributions. Infrared (IR) neural stimulation, a label-free photothermal neuromodulation technique using pulsed IR light, has demonstrated promise but lacks standardized, high-resolution dosimetry methods. Objective. In this study, we present an automated, imaging-based workflow to perform spatially resolved photothermal dosimetry. This method uses thermal lensing to mark the location of IR exposure within the imaging field of view, enabling precise assessment of the radiant exposure dosage and correlated neuronal responses. Approach. Neuronal Ca2+responses to single IR pulses of varying duration (350 µs, 2 ms, and 8 ms) were measured using widefield fluorescence microscopy. The thermal lensing artifact (TLA) observed during stimulation was used to model the spatial energy distribution of the laser beam profile. Neuronal Ca2+ responses were analyzed relative to the local radiant exposure, H 0(x,y), and the average radiant exposure, dosage, Havg, calculated using the laser pulse energy divided by the laser spot area. Main results. The TLA provided a reliable fiducial for tracking the IR stimulus within the imaging field. Neuronal responses to INS were spatially dependent and exhibited three phenotypes: unreactive, low-amplitude, and high-amplitude. The Gaussian laser beam profile led to cells near the beam center receiving higher radiant exposure dosages, exceeding activation thresholds. We find that shorter pulse durations required lower radiant exposure dosages to elicit neuronal responses. The H avg consistently underestimates the radiant exposure required for stimulation. The H 0(x,y) required for stimulation did not produce measurable cellular damage. Significance. Local radiant exposure dosage dictates neuronal activation during INS. Our method provides a standardized, high-throughput approach for performing spatially resolved photothermal dosimetry at microscopic level.

Idioma originalEnglish (US)
Número de artículo066028
PublicaciónJournal of Neural Engineering
Volumen22
N.º6
DOI
EstadoPublished - dic 1 2025

ASJC Scopus subject areas

  • Biomedical Engineering
  • Cellular and Molecular Neuroscience

Huella

Profundice en los temas de investigación de 'Thermal lensing during infrared neural stimulation enables spatially resolved photothermal dosimetry'. En conjunto forman una huella única.

Citar esto