TY - JOUR
T1 - The effect of continuous positive airway pressure on inferior vena cava collapsibility as measured by bedside ultrasound
AU - Solis-McCarthy, Jessica
AU - Gelabert, Christopher
AU - Michalek, Joel
AU - Sisson, Craig
N1 - Funding Information:
and support: By JACEP Open policy, all authors are required to disclose any and all commercial, financial, and other relationships in any way related to the subject of this article as per ICMJE conflict of interest guidelines (see www.icmje.org). The authors have stated that no such relationships exist.Special thanks to Philips for donating materials including the CPAP masks, tubing circuits, and filters and University Hospital Respiratory Care Center for Clinical Excellence for loaning the CPAP machine for research purposes. Additional thanks to the medical students from University of Texas (UT) Health San Antonio Long School of Medicine and the officers of the Ultrasound Interest Group from the academic year 2017–2019, the faculty and staff of the UT Health San Antonio Emergency Department as well as Dr. Nicolas Spampinato (N.S.), Dr. Jeffery Ford (J.F.), and Dr. Angela Schafer (A.F.) for volunteering in this research project.
Publisher Copyright:
© 2022 The Authors. JACEP Open published by Wiley Periodicals LLC on behalf of American College of Emergency Physicians.
PY - 2022/12
Y1 - 2022/12
N2 - Objectives: The purpose of this study was to determine the impact of progressively increasing continuous positive airway pressure (CPAP) on measurements of the caval index (CI) using bedside ultrasound at the 3 common inferior vena cava (IVC) evaluation sites. Methods: This was a prospective, observational trial that included 165 healthy adults over 18 years old enrolled between February 2015 and May 2018. Measurements of the IVC were obtained during normal tidal respirations from the subxiphoid area in the long and short axis and from the right mid-axillary line in the long axis. Measurements were obtained in each of these locations at atmospheric pressure and with CPAP at 5, 10, and 15 cmH2O. The CI was then calculated for each of the 3 selected locations at each level of pressure. Results: As CPAP pressures increased from 0 to 15 cmH2O the CI measurements obtained at the lateral mid-axillary line did not show any statistically significant variation. There was a statistically significant difference (P < 0.001) when comparing measurements of the CI from the lateral mid-axillary line location to both anterior locations. As CPAP pressures increased, the CI calculated from the subxiphoid area in both the anterior short and anterior long axis orientations initially trended upwards at 5 cmH2O, then began to downtrend as the pressures increased to 10 and 15 cmH2O. Comparing the CI measurements from the anterior long and anterior short axis at 0, 5, 10, and 15 cmH2O, there was no statistically significant difference at any pressure (P > 0.05). Conclusion: When evaluating the IVC in a spontaneously breathing patient, measurements from an anterior orientation are preferred as the lateral mid-axillary view can underestimate CI calculations.
AB - Objectives: The purpose of this study was to determine the impact of progressively increasing continuous positive airway pressure (CPAP) on measurements of the caval index (CI) using bedside ultrasound at the 3 common inferior vena cava (IVC) evaluation sites. Methods: This was a prospective, observational trial that included 165 healthy adults over 18 years old enrolled between February 2015 and May 2018. Measurements of the IVC were obtained during normal tidal respirations from the subxiphoid area in the long and short axis and from the right mid-axillary line in the long axis. Measurements were obtained in each of these locations at atmospheric pressure and with CPAP at 5, 10, and 15 cmH2O. The CI was then calculated for each of the 3 selected locations at each level of pressure. Results: As CPAP pressures increased from 0 to 15 cmH2O the CI measurements obtained at the lateral mid-axillary line did not show any statistically significant variation. There was a statistically significant difference (P < 0.001) when comparing measurements of the CI from the lateral mid-axillary line location to both anterior locations. As CPAP pressures increased, the CI calculated from the subxiphoid area in both the anterior short and anterior long axis orientations initially trended upwards at 5 cmH2O, then began to downtrend as the pressures increased to 10 and 15 cmH2O. Comparing the CI measurements from the anterior long and anterior short axis at 0, 5, 10, and 15 cmH2O, there was no statistically significant difference at any pressure (P > 0.05). Conclusion: When evaluating the IVC in a spontaneously breathing patient, measurements from an anterior orientation are preferred as the lateral mid-axillary view can underestimate CI calculations.
KW - caval index
KW - continuous positive airway pressure
KW - inferior vena cava
KW - point-of-care ultrasound
UR - http://www.scopus.com/inward/record.url?scp=85144919047&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85144919047&partnerID=8YFLogxK
U2 - 10.1002/emp2.12856
DO - 10.1002/emp2.12856
M3 - Article
AN - SCOPUS:85144919047
SN - 2688-1152
VL - 3
JO - Journal of the American College of Emergency Physicians Open
JF - Journal of the American College of Emergency Physicians Open
IS - 6
M1 - e12856
ER -