Separation and quantitation of cytochromecoxidase subunits by mono-Q fast protein liquid chromatography and C18 reverse-phase high-performance liquid chromatography

Yuan Chao Liu, Linda H. Sowdal, Neal C. Robinson

Resultado de la investigación: Articlerevisión exhaustiva

26 Citas (Scopus)

Resumen

Mono-Q fast protein liquid chromatography (FPLC) combined with C18 reverse-phase HPLC was used for quantitative subunit analysis of bovine heart cytochromecoxidase, a multisubunit membrane complex. By this approach normal cytochromecoxidase preparations were shown to be a mixture of enzyme that has all 13 subunits and complexes that are missing 1-3 subunits. A distinct advantage of this procedure is that homogeneous 13- or 11-subunit enzyme can be easily isolated from heterogeneous cytochromecoxidase mixtures. The method involves: (1) separation of complexes that are depleted of subunits using Mono-Q FPLC and (2) quantitative subunit analysis of the purified complexes by C18 reverse-phase HPLC with a water/acetonitrile gradient in 0.1% trifluoroacetic acid. The approach has four distinct advantages over other methods of analysis, e.g., sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) or C4 reverse-phase HPLC. (1) The reproducible yield and the baseline resolution between each eluting subunit permits quantitative determination of the subunit content with an accuracy of ± 5%. (2) Subunits that are very difficult to separate by SDS-PAGE, e.g., subunits VIa, VIb, and VIc, are completely resolved by this system. (3) The combination of Mono-Q purification and C18 reverse-phase HPLC analysis permits an accurate assessment of both homogeneity and subunit content. (4) The quantitative nature of the reverse-phase HPLC system also makes it a powerful method for analyzing the specificity and extent of chemical modification of specific subunits as is shown by the difference in reac tivity of subunit VIa towardN-iodoacetylamidoethyl-1-aminonaphthalene-5-sulfonate and 4, 4′-dipyridyl disulfide.

Idioma originalEnglish (US)
Páginas (desde-hasta)135-142
Número de páginas8
PublicaciónArchives of Biochemistry and Biophysics
Volumen324
N.º1
DOI
EstadoPublished - dic 1 1995
Publicado de forma externa

ASJC Scopus subject areas

  • Biophysics
  • Biochemistry
  • Molecular Biology

Huella

Profundice en los temas de investigación de 'Separation and quantitation of cytochromecoxidase subunits by mono-Q fast protein liquid chromatography and C18 reverse-phase high-performance liquid chromatography'. En conjunto forman una huella única.

Citar esto