Rough titanium alloys regulate osteoblast production of angiogenic factors

Rene Olivares-Navarrete, Sharon L. Hyzy, Rolando A. Gittens I, Jennifer M. Schneider, David A. Haithcock, Peter F. Ullrich, Paul J. Slosar, Zvi Schwartz, Barbara D. Boyan

Resultado de la investigación: Articlerevisión exhaustiva

90 Citas (Scopus)

Resumen

Background context: Polyether-ether-ketone (PEEK) and titanium-aluminum- vanadium (titanium alloy) are used frequently in lumbar spine interbody fusion. Osteoblasts cultured on microstructured titanium generate an environment characterized by increased angiogenic factors and factors that inhibit osteoclast activity mediated by integrin α2β1 signaling. It is not known if this is also true of osteoblasts on titanium alloy or PEEK. Purpose: The purpose of this study was to determine if osteoblasts generate an environment that supports angiogenesis and reduces osteoclastic activity when grown on smooth titanium alloy, rough titanium alloy, or PEEK. Study design: This in vitro study compared angiogenic factor production and integrin gene expression of human osteoblast-like MG63 cells cultured on PEEK or titanium-aluminum-vanadium (titanium alloy). Methods: MG63 cells were grown on PEEK, smooth titanium alloy, or rough titanium alloy. Osteogenic microenvironment was characterized by secretion of osteoprotegerin and transforming growth factor beta-1 (TGF-β1), which inhibit osteoclast activity and angiogenic factors including vascular endothelial growth factor A (VEGF-A), fibroblast growth factor 2 (FGF-2), and angiopoietin-1 (ANG-1). Expression of integrins, transmembrane extracellular matrix recognition proteins, was measured by real-time polymerase chain reaction. Results: Culture on titanium alloy stimulated osteoprotegerin, TGF-β1, VEGF-A, FGF-2, and angiopoietin-1 production, and levels were greater on rough titanium alloy than on smooth titanium alloy. All factors measured were significantly lower on PEEK than on smooth or rough titanium alloy. Culture on titanium alloy stimulated expression of messenger RNA for integrins that recognize Type I collagen in comparison with PEEK. Conclusions: Rough titanium alloy stimulated cells to create an osteogenic-angiogenic microenvironment. The osteogenic-angiogenic responses to titanium alloy were greater than PEEK and greater on rough titanium alloy than on smooth titanium alloy. Surface features regulated expression of integrins important in collagen recognition. These factors may increase bone formation, enhance integration, and improve implant stability in interbody spinal fusions.

Idioma originalEnglish (US)
Páginas (desde-hasta)1563-1570
Número de páginas8
PublicaciónSpine Journal
Volumen13
N.º11
DOI
EstadoPublished - nov 2013

ASJC Scopus subject areas

  • Surgery
  • Orthopedics and Sports Medicine
  • Clinical Neurology

Huella

Profundice en los temas de investigación de 'Rough titanium alloys regulate osteoblast production of angiogenic factors'. En conjunto forman una huella única.

Citar esto