Reproducibility and Repeatability of Intravoxel Incoherent Motion MRI Acquisition Methods in Liver

Juan A. Vasquez, Marissa Brown, Mary Woolsey, Mohammad Abdul-Ghani, Venkata Katabathina, Shengwen Deng, John Blangero, Geoffrey D. Clarke

Producción científica: Articlerevisión exhaustiva

3 Citas (Scopus)

Resumen

Background: Intravoxel incoherent motion (IVIM) diffusion weighted MRI (DWI) has potential for evaluating hepatic fibrosis but image acquisition technique influence on diffusion parameter estimation bears investigation. Purpose: To minimize variability and maximize repeatably in abdominal DWI in terms of IVIM parameter estimates. Study Type: Prospective test–retest and image quality comparison. Subjects: Healthy volunteers (3F/7M, 29.9 ± 12.9 years) and Family Study subjects (18F/12M, 51.7 ± 16.7 years), without and with liver steatosis. Field Strength/Sequence: Abdominal single-shot echo-planar imaging (EPI) and simultaneous multi-slice (SMS) DWI sequences with respiratory triggering (RT), breath-holding (BH), and navigator echo (NE) at 3 Tesla. Assessment: SMS-BH, EPI-NE, and SMS-RT data from twice-scanned healthy volunteers were analyzed using 6 × b-values (0–800 s⋅mm−2) and lower (LO) and higher (HI) b-value ranges. Family Study subjects were scanned using SMS and standard EPI sequences. The biexponential IVIM model was used to estimate fast-diffusion coefficient (Df), fraction of fast diffusion (f), and slow-diffusion coefficient (Ds). Scan time, estimated signal-to-noise ratio (eSNR), eSNR per acquisition, and distortion ratio were compared. Statistical Tests: Coefficients of variation (CoV) and Bland Altman analyses were performed for test–retest repeatability. Interclass correlation coefficient (ICC) assessed interobserver agreement with P < 0.05 deemed significant. Results: Within-subject CoVs among volunteers (N = 10) for f and Ds were lowest in EPI-NE-LO (11.6%) and SMS-RT-HI (11.1%). Inter-observer ICCs for f and Ds were highest for EPI-NE-LO (0.63) and SMS-RT-LO (0.76). Df could not be estimated for most subjects. Estimated eSNR (EPI = 21.9, SMS = 4.7) and eSNR time (EPI = 6.7, SMS = 16.6) were greater for SMS, with less distortion in the liver region (DR-PE: EPI = 23.6, SMS = 13.1). Data Conclusion: Simultaneous multislice acquisitions had significantly less variability and higher ICCs of Ds, higher eSNR, less distortion, and reduced scan time compared to EPI. Evidence Level: 2. Technical Efficacy: Stage 1.

Idioma originalEnglish (US)
Páginas (desde-hasta)1691-1703
Número de páginas13
PublicaciónJournal of Magnetic Resonance Imaging
Volumen60
N.º4
DOI
EstadoPublished - oct 2024

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Huella

Profundice en los temas de investigación de 'Reproducibility and Repeatability of Intravoxel Incoherent Motion MRI Acquisition Methods in Liver'. En conjunto forman una huella única.

Citar esto