Quality control limits for fluconazole disk susceptibility tests on Mueller-Hinton agar with glucose and methylene blue

A. Barry, J. Bille, S. Brown, D. Ellis, J. Meis, M. Pfaller, R. Rennie, M. Rinaldi, T. Rogers, M. Traczewski

Resultado de la investigación: Articlerevisión exhaustiva

21 Citas (Scopus)

Resumen

An international collaborative study was performed in order to propose quality control limits for fluconazole disk diffusion susceptibility tests on Mueller-Hinton agar with 2% glucose and 0.5 μg of methylene blue per ml. The supplements may be added before autoclaving the agar, or Mueller-Hinton agar plates may be flooded with a glucose-methylene blue solution. Replicate tests on both types of agar plates generated data to propose zone size limits for tests of Candida parapsilosis ATCC 22019 (22 to 33 mm), C. tropicalis ATCC 750 (26 to 37 mm), and C. albicans ATCC 90028 (28 to 39 mm). C. krusei ATCC 6258 was not useful for this purpose.

Idioma originalEnglish (US)
Páginas (desde-hasta)3410-3412
Número de páginas3
PublicaciónJournal of clinical microbiology
Volumen41
N.º7
DOI
EstadoPublished - jul 1 2003
Publicado de forma externa

ASJC Scopus subject areas

  • Microbiology (medical)

Huella

Profundice en los temas de investigación de 'Quality control limits for fluconazole disk susceptibility tests on Mueller-Hinton agar with glucose and methylene blue'. En conjunto forman una huella única.

Citar esto