T1 - Modification of a Transvalvular Microaxial Flow Pump for Instantaneous Determination of Native Cardiac Output and Volume
AU - ASLAM, M. IMRAN
AU - GRUSLOVA, ALEKSANDRA B.
AU - ALMOMANI, AHMED
AU - NOLEN, D. R.E.W.
AU - ELLIOTT, JAMES J.
AU - JANI, VIVEK P.
AU - KOTTAM, A. N.I.L.
AU - PORTERFIELD, J. O.H.N.
AU - HEIGHTEN, C. L.A.Y.
AU - ANDERSON, ALLEN S.
AU - VALVANO, JONATHAN W.
AU - Feldman, Marc D
N1 - Publisher Copyright:
© 2023 The Authors
PY - 2023/10
Y1 - 2023/10
N2 - Background: The current Impella cardiopulmonary (CP) pump, used for mechanical circulatory support in patients with cardiogenic shock (CS), cannot assess native cardiac output (CO) and left ventricular (LV) volumes. These data are valuable in facilitating device management and weaning. Admittance technology allows for accurate assessment of cardiac chamber volumes. Objectives: This study tested the ability to engineer admittance electrodes onto an existing Impella CP pump to assess total and native CO as well as LV chamber volumes in an instantaneous manner. Methods: Impella CP pumps were fitted with 4 admittance electrodes and were placed in the LVs of adult swine (n = 9) that were subjected to 3 different hemodynamic conditions, including Impella CP speed adjustments, administration of escalating doses of dobutamine and microsphere injections into the left main artery to result in cardiac injury. CO, according to admittance electrodes, was calculated from LV volumes and heart rate. In addition, CO was calculated in each instance via thermodilution, continuous CO measurement, the Fick principle, and aortic velocity-time integral by means of echocardiography. Results: Modified Impella CP pumps were placed in swine LVs successfully. CO, as determined by admittance electrodes, was similar by trend to other methods of CO assessment. It was corrected for pump speed to calculate native CO, and calculated LV chamber volumes trended as expected in each experimental protocol. Conclusions: We report, for the first time, that an Impella CP pump can be fitted with admittance electrodes and used to determine total and native CO in various hemodynamic situations. Condensed Abstract: Transvalvular mechanical circulatory support devices such as the Impella CP do not have the ability to provide real-time information on native cardiac output (CO) and left ventricular (LV) volumes. This information is critical in device management and in weaning in patients with cardiogenic shock. We demonstrate, for the first time, that Impella CP pumps coupled with admittance electrodes are able to determine native CO and LV chamber volumes in multiple hemodynamic situations such as Impella pump speed adjustments, escalating dobutamine administration and cardiac injury from microsphere injection.
AB - Background: The current Impella cardiopulmonary (CP) pump, used for mechanical circulatory support in patients with cardiogenic shock (CS), cannot assess native cardiac output (CO) and left ventricular (LV) volumes. These data are valuable in facilitating device management and weaning. Admittance technology allows for accurate assessment of cardiac chamber volumes. Objectives: This study tested the ability to engineer admittance electrodes onto an existing Impella CP pump to assess total and native CO as well as LV chamber volumes in an instantaneous manner. Methods: Impella CP pumps were fitted with 4 admittance electrodes and were placed in the LVs of adult swine (n = 9) that were subjected to 3 different hemodynamic conditions, including Impella CP speed adjustments, administration of escalating doses of dobutamine and microsphere injections into the left main artery to result in cardiac injury. CO, according to admittance electrodes, was calculated from LV volumes and heart rate. In addition, CO was calculated in each instance via thermodilution, continuous CO measurement, the Fick principle, and aortic velocity-time integral by means of echocardiography. Results: Modified Impella CP pumps were placed in swine LVs successfully. CO, as determined by admittance electrodes, was similar by trend to other methods of CO assessment. It was corrected for pump speed to calculate native CO, and calculated LV chamber volumes trended as expected in each experimental protocol. Conclusions: We report, for the first time, that an Impella CP pump can be fitted with admittance electrodes and used to determine total and native CO in various hemodynamic situations. Condensed Abstract: Transvalvular mechanical circulatory support devices such as the Impella CP do not have the ability to provide real-time information on native cardiac output (CO) and left ventricular (LV) volumes. This information is critical in device management and in weaning in patients with cardiogenic shock. We demonstrate, for the first time, that Impella CP pumps coupled with admittance electrodes are able to determine native CO and LV chamber volumes in multiple hemodynamic situations such as Impella pump speed adjustments, escalating dobutamine administration and cardiac injury from microsphere injection.
KW - Impella
KW - admittance
KW - cardiac output
KW - cardiogenic shock
KW - mechanical circulatory support
KW - thermodilution
UR - http://www.scopus.com/inward/record.url?scp=85160065029&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85160065029&partnerID=8YFLogxK
U2 - 10.1016/j.cardfail.2023.04.007
DO - 10.1016/j.cardfail.2023.04.007
M3 - Article
C2 - 37105397
AN - SCOPUS:85160065029
SN - 1071-9164
VL - 29
SP - 1369
EP - 1379
JO - Journal of Cardiac Failure
JF - Journal of Cardiac Failure
IS - 10
ER -