Resumen
The biocompatibility of titanium with human tissue is well established; its potential as an alternate metal for crown restorations has yet to be fully investigated. This study measured the geometry and accuracy of coping margins cast in Ti, 99.5% chemically pure. Twenty castings with 45-degree facial and 90-degree palatal margins were made by indirect technique with a commercial system using recommended procedures. They were then cemented with ZnPO4 cement. The coping and die assemblies were embedded in resin, sectioned longitudinally, and measured with a microscope at × 50 power. Casting shrinkage was characteristic, particularly along the horizontal axis in the plane of the shoulder. Although horizontal linear shrinkage of 45-degree margins was greater than that for the 90-degree form, the surface of marginal discrepancy was greatest with the 90-degree configuration.
| Idioma original | English (US) |
|---|---|
| Páginas (desde-hasta) | 435-440 |
| Número de páginas | 6 |
| Publicación | The Journal of Prosthetic Dentistry |
| Volumen | 67 |
| N.º | 4 |
| DOI | |
| Estado | Published - abr 1992 |