TY - JOUR
T1 - Magnetic susceptibility effects and their application in the development of new ferromagnetic catheters for magnetic resonance imaging
AU - Rubin, Daniel L.
AU - Ratner, Adam V.
AU - Young, Stuart W.
PY - 1990/12
Y1 - 1990/12
N2 - Rubin DL, Ratner AV, Young SW. Magnetic susceptibility effects and their application in the development of new ferromagnetic catheters for magnetic resonance imaging. Invest Radiol 1990;25:1325–1332. Newly developed ferromagnetic catheters (Fe-Caths) are more conspicuous than conventional radiographic catheters (Rad-Caths) on magnetic resonance (MR) images because they produce recognizable ferromagnetic signal patterns (FSPs). To determine how MRI parameters influence these patterns, the imaging characteristics of nine Fe-Caths (ferromagnetic concentration 0.01 to 1.0 weight/weight,%) were studied systematically and compared with three Rad-Caths. All catheters were studied in stationary and moving phantoms at mid-field (0.38 T) and high-field (1.5 T) strength using spin-echo and gradient-echo pulse sequences. Rad-Caths always produced a signal void. Fe-Caths produced FSPs, the size of which depended on the orientation of the catheter with respect to the main magnetic field, the concentration of ferromagnetic agent in the catheter, and the direction and strength of the frequency encoding gradient. When Fe-Caths were positioned perpendicudar to the main magnetic field, they produced FSPs; however, when they were parallel to the main magnetic field, Fe-Caths produced no FSP, thus having a similar appearance to the Rad-Caths. Ferromagnetic catheters produce conspicuous patterns on MR images that depend on catheter orientation in the main magnetic field and vary predictably with the MRI parameters.
AB - Rubin DL, Ratner AV, Young SW. Magnetic susceptibility effects and their application in the development of new ferromagnetic catheters for magnetic resonance imaging. Invest Radiol 1990;25:1325–1332. Newly developed ferromagnetic catheters (Fe-Caths) are more conspicuous than conventional radiographic catheters (Rad-Caths) on magnetic resonance (MR) images because they produce recognizable ferromagnetic signal patterns (FSPs). To determine how MRI parameters influence these patterns, the imaging characteristics of nine Fe-Caths (ferromagnetic concentration 0.01 to 1.0 weight/weight,%) were studied systematically and compared with three Rad-Caths. All catheters were studied in stationary and moving phantoms at mid-field (0.38 T) and high-field (1.5 T) strength using spin-echo and gradient-echo pulse sequences. Rad-Caths always produced a signal void. Fe-Caths produced FSPs, the size of which depended on the orientation of the catheter with respect to the main magnetic field, the concentration of ferromagnetic agent in the catheter, and the direction and strength of the frequency encoding gradient. When Fe-Caths were positioned perpendicudar to the main magnetic field, they produced FSPs; however, when they were parallel to the main magnetic field, Fe-Caths produced no FSP, thus having a similar appearance to the Rad-Caths. Ferromagnetic catheters produce conspicuous patterns on MR images that depend on catheter orientation in the main magnetic field and vary predictably with the MRI parameters.
KW - Catheterization
KW - Ferromagnetism
KW - Magnetic resonance
KW - Magnetic susceptibility
UR - http://www.scopus.com/inward/record.url?scp=0025674137&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0025674137&partnerID=8YFLogxK
U2 - 10.1097/00004424-199012000-00010
DO - 10.1097/00004424-199012000-00010
M3 - Article
C2 - 2279913
AN - SCOPUS:0025674137
SN - 0020-9996
VL - 25
SP - 1325
EP - 1332
JO - Investigative Radiology
JF - Investigative Radiology
IS - 12
ER -