Low-dose head computed tomography in children: A single institutional experience in pediatric radiation risk reduction

Ryan P. Morton, Renee M. Reynolds, Rohan Ramakrishna, Michael R. Levitt, Richard A. Hopper, Amy Lee, Samuel R. Browd

Producción científica: Articlerevisión exhaustiva

47 Citas (Scopus)

Resumen

Object. In this study, the authors describe their experience with a low-dose head CT protocol for a preselected neurosurgical population at a dedicated pediatric hospital (Seattle Children's Hospital), the largest number of patients with this protocol reported to date. Methods. All low-dose head CT scans between October 2011 and November 2012 were reviewed. Two different low-dose radiation dosages were used, at one-half or one-quarter the dose of a standard head CT scan, based on patient characteristics agreed upon by the neurosurgery and radiology departments. Patient information was also recorded, including diagnosis and indication for CT scan. Results. Six hundred twenty-four low-dose head CT procedures were performed within the 12-month study period. Although indications for the CT scans varied, the most common reason was to evaluate the ventricles and catheter placement in hydrocephalic patients with shunts (70%), followed by postoperative craniosynostosis imaging (12%). These scans provided adequate diagnostic imaging, and no patient required a follow-up full-dose CT scan as a result of poor image quality on a low-dose CT scan. Overall physician comfort and satisfaction with interpretation of the images was high. An additional 2150 full-dose head CT scans were performed during the same 12-month time period, making the total number of CT scans 2774. This value compares to 3730 full-dose head CT scans obtained during the year prior to the study when low-dose CT and rapid-sequence MRI was not a reliable option at Seattle Children's Hospital. Thus, over a 1-year period, 22% of the total CT scans were able to be converted to low-dose scans, and full-dose CT scans were able to be reduced by 42%. Conclusions. The implementation of a low-dose head CT protocol substantially reduced the amount of ionizing radiation exposure in a preselected population of pediatric neurosurgical patients. Image quality and diagnostic utility were not significantly compromised.

Idioma originalEnglish (US)
Páginas (desde-hasta)406-410
Número de páginas5
PublicaciónJournal of Neurosurgery: Pediatrics
Volumen12
N.º4
DOI
EstadoPublished - oct 2013
Publicado de forma externa

ASJC Scopus subject areas

  • Clinical Neurology
  • Surgery
  • Pediatrics, Perinatology, and Child Health

Huella

Profundice en los temas de investigación de 'Low-dose head computed tomography in children: A single institutional experience in pediatric radiation risk reduction'. En conjunto forman una huella única.

Citar esto