Resumen
We describe the case of a patient with an ascending aortic aneurysm who underwent valve-in-valve transcatheter aortic valve implantation, which was complicated by valve embolization. After a multidisciplinary discussion and an innovative approach, the free-floating embolized valve was anchored securely in the aortic arch with an uncovered aortic endovascular stent. (Level of Difficulty: Intermediate.)
Idioma original | English (US) |
---|---|
Número de artículo | 101598 |
Publicación | JACC: Case Reports |
Volumen | 7 |
DOI | |
Estado | Published - feb 1 2023 |
ASJC Scopus subject areas
- Cardiology and Cardiovascular Medicine