Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Expandable intrahepatic portacaval shunt stents: Early experience in the dog

Producción científica: Article › revisión exhaustiva

Resumen

Intrahepatic portacaval shunts were established in dogs by the transjugular approach. The shunts extended from the anterior aspect of the inferior vena cava to the portal bifurcation through interposed liver parenchyma. The tissue track was created by a long transjugular needle and enlarged by balloon angioplasty catheter dilatation. The opening was then stented with a specially made, expandable, tubular, woven mesh of stainless steel wire. The stent was introduced mounted in a collapsed fashion around a folded angioplasty balloon. Inflation of the balloon expanded the stent and the tissue track simultaneously, leaving a large side-to-side portacaval shunt. Nine out of 12 animals survived the procedure and eight of them had functioning shunts as long as 9 months after placement. Pathologic examination showed complete endothelialization of the inner surface of the stents.

Idioma originalEnglish (US)
Páginas (desde-hasta)821-825
Número de páginas5
PublicaciónAmerican Journal of Roentgenology
Volumen145
N.º4
DOI
EstadoPublished - 1985
Publicado de forma externaSí

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Huella

Profundice en los temas de investigación de 'Expandable intrahepatic portacaval shunt stents: Early experience in the dog'. En conjunto forman una huella única.

Citar esto