T1 - Evaluation of C-arm CT metal artifact reduction algorithm during intra-aneurysmal coil embolization
T2 - Assessment of brain parenchyma, stents and flow-diverters
AU - Chintalapani, Gouthami
AU - Chinnadurai, Ponraj
AU - Srinivasan, Visish
AU - Chen, Stephen R.
AU - Shaltoni, Hashem
AU - Morsi, Hesham
AU - Mawad, Michel E.
AU - Kan, Peter
N1 - Publisher Copyright:
© 2016 Elsevier Ireland Ltd.
Copyright:
Copyright 2017 Elsevier B.V., All rights reserved.
PY - 2016/7/1
Y1 - 2016/7/1
N2 - Purpose Flat panel C-arm CT images acquired in the interventional suite provide valuable information regarding brain parenchyma, vasculature, and device status during the procedure. However, these images often suffer from severe streak artifacts due to the presence of metallic objects such as coils. These artifacts limit the capability to make diagnostic inferences and thus need to be reduced for better image interpretation. The main purpose of this paper is to systematically evaluate the accuracy of one such C-arm CT based metal artifact reduction (MAR) algorithm and to demonstrate its usage in both stent and flow diverter assisted coil embolization procedures. Methods C-arm CT images routinely acquired in 24 patients during coil embolization procedure (stent-assisted (12) and flow-diverter assisted (12)) were included in this study in a retrospective fashion. These images were reconstructed without and with MAR algorithm on an offline workstation and compared using quantitative image analysis metrics. This analysis was carried out to assess the improvements in both brain parenchyma and device visibility with MAR algorithm. Further, ground truth reference images from phantom experiments and clinical data were used for accurate assessment. Results Quantitative image analysis of brain parenchyma showed uniform distribution of grayscale values and reduced image noise after MAR correction. The line profile plot analysis of device profile in both phantom and clinical data demonstrated improved device visibility with MAR correction. Conclusions MAR algorithm successfully reduced streak artifacts from coil embolization in all cases, thus allowing more accurate assessment of devices and adjacent brain parenchyma.
AB - Purpose Flat panel C-arm CT images acquired in the interventional suite provide valuable information regarding brain parenchyma, vasculature, and device status during the procedure. However, these images often suffer from severe streak artifacts due to the presence of metallic objects such as coils. These artifacts limit the capability to make diagnostic inferences and thus need to be reduced for better image interpretation. The main purpose of this paper is to systematically evaluate the accuracy of one such C-arm CT based metal artifact reduction (MAR) algorithm and to demonstrate its usage in both stent and flow diverter assisted coil embolization procedures. Methods C-arm CT images routinely acquired in 24 patients during coil embolization procedure (stent-assisted (12) and flow-diverter assisted (12)) were included in this study in a retrospective fashion. These images were reconstructed without and with MAR algorithm on an offline workstation and compared using quantitative image analysis metrics. This analysis was carried out to assess the improvements in both brain parenchyma and device visibility with MAR algorithm. Further, ground truth reference images from phantom experiments and clinical data were used for accurate assessment. Results Quantitative image analysis of brain parenchyma showed uniform distribution of grayscale values and reduced image noise after MAR correction. The line profile plot analysis of device profile in both phantom and clinical data demonstrated improved device visibility with MAR correction. Conclusions MAR algorithm successfully reduced streak artifacts from coil embolization in all cases, thus allowing more accurate assessment of devices and adjacent brain parenchyma.
KW - C-arm/conebeam/flatpanel CT
KW - Coiling
KW - Flow diverters
KW - MAR
KW - Metal artifacts
KW - Stents
UR - http://www.scopus.com/inward/record.url?scp=84967327878&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84967327878&partnerID=8YFLogxK
U2 - 10.1016/j.ejrad.2016.04.013
DO - 10.1016/j.ejrad.2016.04.013
M3 - Article
C2 - 27235879
AN - SCOPUS:84967327878
VL - 85
SP - 1312
EP - 1321
JO - European Journal of Radiology
JF - European Journal of Radiology
SN - 0720-048X
IS - 7
ER -