TY - JOUR
T1 - Effects of intravenous, sternal, and humerus intraosseous administration of Hextend on time of administration and hemodynamics in a hypovolemic swine model
AU - Blouin, Dawn
AU - Gegel, Brian T.
AU - Johnson, Don
AU - Garcia-Blanco, Jose C.
PY - 2016/1/1
Y1 - 2016/1/1
N2 - OBJECTIVE: To determine if there were significant differences among humerus intraosseous (HIO), sternal intraosseous (SIO), and intravenous (IV) administration of 500 mL Hextend in hemodynamics or administration time in a hypovolemic swine model.Vivarium.SUBJECTS: Yorkshire swine; sample size was based on a large effect size of 0.5, an α of 0.05, and a power of 80 percent Swine were randomly assigned to one of four groups: HIO (n = 9), SIO (n = 9), IV (n = 9), and control (n = 9).INTERVENTION: Swine were exsanguinated 30 percent of their blood volume. Hextend (500 mL) was administered by either the HIO, SIO, or IV route; the control group received none.MAIN OUTCOME: Time of administration of Hextend; systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), heart rate (HR), cardiac output (CO), and stroke volume (SV) data were collected every 2 minutes and compared by group over 8 minutes.RESULTS: A repeated analysis of variance found that there were no significant differences in SBP, DBP, MAP, HR, CO, and SV among HIO, SIO, and IV groups over 8 minutes (p > 0.05). An analyses of variance determined that there was no significant difference between groups relative to time of administration (p = 0.521).CONCLUSION: When IV access is difficult, both HIO and SIO are effective techniques for rapid vascular access and the administration of Hextend for patients in hypovolemic shock.
AB - OBJECTIVE: To determine if there were significant differences among humerus intraosseous (HIO), sternal intraosseous (SIO), and intravenous (IV) administration of 500 mL Hextend in hemodynamics or administration time in a hypovolemic swine model.Vivarium.SUBJECTS: Yorkshire swine; sample size was based on a large effect size of 0.5, an α of 0.05, and a power of 80 percent Swine were randomly assigned to one of four groups: HIO (n = 9), SIO (n = 9), IV (n = 9), and control (n = 9).INTERVENTION: Swine were exsanguinated 30 percent of their blood volume. Hextend (500 mL) was administered by either the HIO, SIO, or IV route; the control group received none.MAIN OUTCOME: Time of administration of Hextend; systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), heart rate (HR), cardiac output (CO), and stroke volume (SV) data were collected every 2 minutes and compared by group over 8 minutes.RESULTS: A repeated analysis of variance found that there were no significant differences in SBP, DBP, MAP, HR, CO, and SV among HIO, SIO, and IV groups over 8 minutes (p > 0.05). An analyses of variance determined that there was no significant difference between groups relative to time of administration (p = 0.521).CONCLUSION: When IV access is difficult, both HIO and SIO are effective techniques for rapid vascular access and the administration of Hextend for patients in hypovolemic shock.
UR - http://www.scopus.com/inward/record.url?scp=85037603448&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85037603448&partnerID=8YFLogxK
U2 - 10.5055/ajdm.2016.0238
DO - 10.5055/ajdm.2016.0238
M3 - Article
C2 - 28134417
AN - SCOPUS:85037603448
SN - 1932-149X
VL - 11
SP - 183
EP - 192
JO - American journal of disaster medicine
JF - American journal of disaster medicine
IS - 3
ER -