Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Donor Tricuspid Annuloplasty During Orthotopic Heart Transplantation: Long-Term Results of a Prospective Controlled Study

  • Valluvan Jeevanandam
  • , Hyde Russell
  • , Paul Mather
  • , Satoshi Furukawa
  • , Allen Anderson
  • , Jaishankar Raman

Producción científica: Article › revisión exhaustiva

Resumen

Background: Development of tricuspid regurgitation after orthotopic heart transplantation can cause heart failure along with renal and hepatic impairment and portends a poor prognosis. If tricuspid regurgitation causes significant symptoms, tricuspid valve repair or replacement is often required. This study was designed to study the effects of prophylactic tricuspid valve annuloplasty (TVA) during orthotopic heart transplantation on long-term survival, renal function, and amount of tricuspid regurgitation. Methods: Between April 1997 and March 1998, 60 patients (aged 18 to 70 years; 22 female) randomly received either standard bicaval orthotopic heart transplantation (group STD; n = 30) or bicaval orthotopic heart transplantation with DeVega TVA (group TVA; n = 30). Tricuspid valve annuloplasty was performed on the donor heart before implantation using pledgeted 2-0 polypropylene and sized to an annulus of 29 mm. Echocardiographic measurements, laboratory values, and hemodynamics were obtained prospectively and reviewed by an independent data analyst. Results: Follow-up of patients as of December 2003 was complete. Although there was a perioperative mortality advantage in group TVA, there was no difference between groups in long-term survival. At the end of the study, however, there was a statistical difference (group STD versus group TVA, p < 0.05) with regard to cardiac mortality (7 of 30 versus 3 of 30), average amount of tricuspid regurgitation (1.5 ± 1.3 versus 0.5 ± 0.4), percentage of patients with 2+ or greater tricuspid regurgitation (34% versus 0%), serum creatinine (2.9 ± 2.0 versus 1.8 ± 0.7), and difference in serum creatinine over baseline (2.0 ± 2.1 versus 0.7 ± 0.8). Conclusions: Prophylactic DeVega TVA of the donor heart is durable and decreases the incidence of cardiac-related mortality and tricuspid regurgitation after orthotopic heart transplantation. In addition, there is improved protection of renal function. Considering the ease and safety of TVA and its advantages, it should be performed as a routine adjunct to orthotopic heart transplantation.

Idioma originalEnglish (US)
Páginas (desde-hasta)2089-2095
Número de páginas7
PublicaciónAnnals of Thoracic Surgery
Volumen82
N.º6
DOI
EstadoPublished - dic 2006
Publicado de forma externaSí

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Pulmonary and Respiratory Medicine
  • Surgery

Huella

Profundice en los temas de investigación de 'Donor Tricuspid Annuloplasty During Orthotopic Heart Transplantation: Long-Term Results of a Prospective Controlled Study'. En conjunto forman una huella única.

Citar esto