TY - JOUR
T1 - Comparison of concentric condensation technique with laterally condensed gutta-percha
AU - Page, Mitchell L.
AU - Hargreaves, Kenneth M.
AU - ElDeeb, Mahmoud
PY - 1995/6
Y1 - 1995/6
N2 - Sixty mandibular premolars with large, straight canals and 60 nonjoining narrow, curved canals from mesial mandibular molar roots were obturated with gutta-percha via 1 of 3 methods: lateral condensation with sealer, concentric condensation with sealer, or concentric condensation without sealer. The sealer used was a zinc oxide-eugenol without radiopacifiers. The premolar teeth were radiographed next to a step wedge, both before and after obturation. All teeth were exposed to India ink as a test for linear dye leakage, then cleared, and the leakage recorded. The pre- and postobturation radiographs were scanned at 2 and 6 mm from the apex using a Joyce-Loebel microdensitometer to establish the radiographic density of the obturation material, and a density ratio for the obturation was calculated using the cross-sectional diameter of the obturating material. The incidence of gutta-percha extrusion and Micro-Flow Compactor breakage was recorded. Two-way analysis of variance for linear dye leakage revealed no significant differences between the lateral and concentric condensation groups when sealer was used (p > 0.05). The concentric condensation without sealer groups exhibited significantly greater leakage (p < 0.00001) than the other groups, showing the importance of using sealers. One-way analysis of variance found no significant differences in radiographic density ratios between groups at 2 mm (p > 0.05) or 6 mm from the apex (p > 0.05). The incidence of extrusion was not significant, but a high rate of #30 condensor breakage was found.
AB - Sixty mandibular premolars with large, straight canals and 60 nonjoining narrow, curved canals from mesial mandibular molar roots were obturated with gutta-percha via 1 of 3 methods: lateral condensation with sealer, concentric condensation with sealer, or concentric condensation without sealer. The sealer used was a zinc oxide-eugenol without radiopacifiers. The premolar teeth were radiographed next to a step wedge, both before and after obturation. All teeth were exposed to India ink as a test for linear dye leakage, then cleared, and the leakage recorded. The pre- and postobturation radiographs were scanned at 2 and 6 mm from the apex using a Joyce-Loebel microdensitometer to establish the radiographic density of the obturation material, and a density ratio for the obturation was calculated using the cross-sectional diameter of the obturating material. The incidence of gutta-percha extrusion and Micro-Flow Compactor breakage was recorded. Two-way analysis of variance for linear dye leakage revealed no significant differences between the lateral and concentric condensation groups when sealer was used (p > 0.05). The concentric condensation without sealer groups exhibited significantly greater leakage (p < 0.00001) than the other groups, showing the importance of using sealers. One-way analysis of variance found no significant differences in radiographic density ratios between groups at 2 mm (p > 0.05) or 6 mm from the apex (p > 0.05). The incidence of extrusion was not significant, but a high rate of #30 condensor breakage was found.
UR - http://www.scopus.com/inward/record.url?scp=0029320905&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0029320905&partnerID=8YFLogxK
U2 - 10.1016/S0099-2399(06)81007-1
DO - 10.1016/S0099-2399(06)81007-1
M3 - Article
C2 - 7673839
AN - SCOPUS:0029320905
SN - 0099-2399
VL - 21
SP - 308
EP - 313
JO - Journal of Endodontics
JF - Journal of Endodontics
IS - 6
ER -