Characterizing atherosclerotic plaque with computed tomography: A contrast-detail study

Nim Kasraiea, Geoffrey David Clarke

Producción científica: Conference contribution

Resumen

Plaque characterization may benefit from the increasing distinctiveness of the attenuating properties of different soft plaque components at lower energies. Due to the relative slight increase in the CT number of the nonadipose soft plaque at lower tube voltage settings vs. adipose plaque, a higher contrast between atheromous adipose and non-adipose plaque may become visible with modern 64 slice systems. A contrast-detail (C-D) phantom with varying plaque composition as the contrast generating method, was imaged on a commercial 64 slice MDCT system using 80, 120, and 140 kVp settings. The same phantom was also imaged on a Cone Beam CT (CBCT) system with a lower tube voltage of 75 kVp. The results of experiments from four different observers on three different plaque types (lipid, fiber, calcific) indicate that CT attenuation within lipid cores and fibrous masses vary not only with the percentage of lipid or fiber present, but also with the size of the cores. Furthermore, the C-D curve analysis for all three plaque types reveals that while the noise constraints prevent visible differentiation of soft plaque at current conventional 64 slice MDCT settings, CBCT exhibits superior visible contrast detectability than its conventional counterpart, with the latter having appreciably better resolution limits and beneficial lower tube voltages. This low voltage CT technique has the potential to be useful in composition based diagnosis of carotid vulnerable atherosclerotic plaque.

Idioma originalEnglish (US)
Título de la publicación alojadaMedical Imaging 2012
Subtítulo de la publicación alojadaImage Perception, Observer Performance, and Technology Assessment
EditoresCraig K. Abbey, Claudia R. Mello-Thoms
EditorialSPIE
ISBN (versión digital)9780819489678
DOI
EstadoPublished - 2012
EventoMedical Imaging 2012: Image Perception, Observer Performance, and Technology Assessment - San Diego, United States
Duración: feb 8 2012feb 9 2012

Serie de la publicación

NombreProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volumen8318
ISSN (versión impresa)1605-7422

Conference

ConferenceMedical Imaging 2012: Image Perception, Observer Performance, and Technology Assessment
País/TerritorioUnited States
CiudadSan Diego
Período2/8/122/9/12

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics
  • Radiology Nuclear Medicine and imaging
  • Biomaterials

Huella

Profundice en los temas de investigación de 'Characterizing atherosclerotic plaque with computed tomography: A contrast-detail study'. En conjunto forman una huella única.

Citar esto