Biomechanical Comparison of Arthroscopic Repair Constructs for Radial Tears of the Meniscus

Eric A. Branch, Charles Milchteim, Bradley S. Aspey, Wei Liu, Justin D. Saliman, Adam W. Anz

Producción científica: Articlerevisión exhaustiva

38 Citas (Scopus)

Resumen

Background: Radial tears of the meniscus represent a challenging clinical scenario because benign neglect and partial meniscectomy have both been shown to have negative biomechanical and long-term clinical consequences. Hypothesis: Complex suture repair constructs have higher failure loads and stiffness values compared with simple constructs. Study Design: Controlled laboratory study. Methods: After radial transection of human cadaveric menisci, simulated tears were repaired arthroscopically by use of 1 of 4 repair constructs: (1) 2 inside-out horizontal sutures, (2) 2 all-inside horizontal sutures, (3) an all-inside Mason-Allen construct consisting of 4 sutures, or (4) an all-inside construct consisting of a figure-of-8 suture plus 1 horizontal suture. Meniscus specimens were harvested and tested to failure on an Instron machine. The Kruskal-Wallis test was used to evaluate for significance of maximal failure load and stiffness between groups. Results: The mean maximum failure loads were 64 ± 20 N (inside-out horizontal construct), 75 ± 16 N (all-inside horizontal construct), 86 ± 19 N (Mason-Allen construct), and 113 ± 22 N (figure-of-8 plus horizontal construct). Interconstruct comparison revealed a statistically significant difference between the figure-of-8 plus horizontal construct and all 3 remaining constructs (P <.02) as well as the Mason-Allen construct when compared with the inside-out horizontal construct (P <.01). Statistical significance was not found between the all-inside horizontal construct and the Mason-Allen construct or between the all-inside horizontal construct and the inside-out horizontal construct (P =.2 and.7, respectively). Stiffness values were lower for the inside-out construct compared with the all-inside constructs (P <.05). Conclusion: Complex all-inside repair constructs had significantly higher failure loads than a conventional, simple inside-out suture repair construct for repair of radial meniscal tears. Stiffness values among the all-inside groups were greater than those for the inside-out group. Clinical Relevance: Arthroscopic techniques are presented to produce stronger radial meniscal tear repairs.

Idioma originalEnglish (US)
Páginas (desde-hasta)2270-2276
Número de páginas7
PublicaciónAmerican Journal of Sports Medicine
Volumen43
N.º9
DOI
EstadoPublished - sept 3 2015
Publicado de forma externa

ASJC Scopus subject areas

  • Physical Therapy, Sports Therapy and Rehabilitation
  • Orthopedics and Sports Medicine

Huella

Profundice en los temas de investigación de 'Biomechanical Comparison of Arthroscopic Repair Constructs for Radial Tears of the Meniscus'. En conjunto forman una huella única.

Citar esto