Use of a physiologic oral glucose solution for screening for impaired glucose tolerance and non-insulin-dependent diabetes mellitus

William T Phillips, Kathryn S. Tilson, Joyce G. Schwartz

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Objective. - To evaluate a lower osmolar, more physiologic oral glucose solution as part of an oral glucose tolerance test and to compare it to the standard glucose solution to see if it could serve as an effective screening agent for patients with impaired glucose tolerance or non-insulin-dependent diabetes mellitus. Methods. - A total of 100 subjects were given both the standard (1.38 mol/L) 75-g oral glucose tolerance test solution and the lower osmolar (0.62 mol/L) 50-g glucose solution. Each test was separated by at least 3 days. Blood samples were drawn at baseline and 30, 60, and 120 minutes after ingestion of each glucose solution. The 1- and 2-hour blood glucose values obtained using the 75-g oral glucose tolerance test beverage were used as the gold standard to diagnose diabetes according to World Health Organization criteria. Results. - Both solutions were shown to have a high sensitivity and specificity for detecting diabetes and impaired glucose tolerance at 30 and 60 minutes. Conclusions. - The physiologic 50-g solution uses less glucose, is highly palatable, and is similar in sweetness and carbohydrate concentration to commonly consumed soda beverages. A larger study including more patients with impaired glucose tolerance will need to be performed to verify our conclusions. The ability to perform high-sensitivity and high-specificity screening for patients with diabetes or impaired glucose tolerance with a single timed blood sample could make mass screening more practical.

Original languageEnglish (US)
Pages (from-to)842-846
Number of pages5
JournalArchives of Pathology and Laboratory Medicine
Volume120
Issue number9
StatePublished - Sep 1996

Fingerprint

Glucose Intolerance
Type 2 Diabetes Mellitus
Glucose
Glucose Tolerance Test
Beverages
Sensitivity and Specificity
Mass Screening
Proxy
Blood Glucose
Eating
Carbohydrates

ASJC Scopus subject areas

  • Pathology and Forensic Medicine
  • Medical Laboratory Technology

Cite this

Use of a physiologic oral glucose solution for screening for impaired glucose tolerance and non-insulin-dependent diabetes mellitus. / Phillips, William T; Tilson, Kathryn S.; Schwartz, Joyce G.

In: Archives of Pathology and Laboratory Medicine, Vol. 120, No. 9, 09.1996, p. 842-846.

Research output: Contribution to journalArticle

@article{7bfba5f08f744611aa1872d9e42e3097,
title = "Use of a physiologic oral glucose solution for screening for impaired glucose tolerance and non-insulin-dependent diabetes mellitus",
abstract = "Objective. - To evaluate a lower osmolar, more physiologic oral glucose solution as part of an oral glucose tolerance test and to compare it to the standard glucose solution to see if it could serve as an effective screening agent for patients with impaired glucose tolerance or non-insulin-dependent diabetes mellitus. Methods. - A total of 100 subjects were given both the standard (1.38 mol/L) 75-g oral glucose tolerance test solution and the lower osmolar (0.62 mol/L) 50-g glucose solution. Each test was separated by at least 3 days. Blood samples were drawn at baseline and 30, 60, and 120 minutes after ingestion of each glucose solution. The 1- and 2-hour blood glucose values obtained using the 75-g oral glucose tolerance test beverage were used as the gold standard to diagnose diabetes according to World Health Organization criteria. Results. - Both solutions were shown to have a high sensitivity and specificity for detecting diabetes and impaired glucose tolerance at 30 and 60 minutes. Conclusions. - The physiologic 50-g solution uses less glucose, is highly palatable, and is similar in sweetness and carbohydrate concentration to commonly consumed soda beverages. A larger study including more patients with impaired glucose tolerance will need to be performed to verify our conclusions. The ability to perform high-sensitivity and high-specificity screening for patients with diabetes or impaired glucose tolerance with a single timed blood sample could make mass screening more practical.",
author = "Phillips, {William T} and Tilson, {Kathryn S.} and Schwartz, {Joyce G.}",
year = "1996",
month = "9",
language = "English (US)",
volume = "120",
pages = "842--846",
journal = "Archives of Pathology and Laboratory Medicine",
issn = "0003-9985",
publisher = "College of American Pathologists",
number = "9",

}

TY - JOUR

T1 - Use of a physiologic oral glucose solution for screening for impaired glucose tolerance and non-insulin-dependent diabetes mellitus

AU - Phillips, William T

AU - Tilson, Kathryn S.

AU - Schwartz, Joyce G.

PY - 1996/9

Y1 - 1996/9

N2 - Objective. - To evaluate a lower osmolar, more physiologic oral glucose solution as part of an oral glucose tolerance test and to compare it to the standard glucose solution to see if it could serve as an effective screening agent for patients with impaired glucose tolerance or non-insulin-dependent diabetes mellitus. Methods. - A total of 100 subjects were given both the standard (1.38 mol/L) 75-g oral glucose tolerance test solution and the lower osmolar (0.62 mol/L) 50-g glucose solution. Each test was separated by at least 3 days. Blood samples were drawn at baseline and 30, 60, and 120 minutes after ingestion of each glucose solution. The 1- and 2-hour blood glucose values obtained using the 75-g oral glucose tolerance test beverage were used as the gold standard to diagnose diabetes according to World Health Organization criteria. Results. - Both solutions were shown to have a high sensitivity and specificity for detecting diabetes and impaired glucose tolerance at 30 and 60 minutes. Conclusions. - The physiologic 50-g solution uses less glucose, is highly palatable, and is similar in sweetness and carbohydrate concentration to commonly consumed soda beverages. A larger study including more patients with impaired glucose tolerance will need to be performed to verify our conclusions. The ability to perform high-sensitivity and high-specificity screening for patients with diabetes or impaired glucose tolerance with a single timed blood sample could make mass screening more practical.

AB - Objective. - To evaluate a lower osmolar, more physiologic oral glucose solution as part of an oral glucose tolerance test and to compare it to the standard glucose solution to see if it could serve as an effective screening agent for patients with impaired glucose tolerance or non-insulin-dependent diabetes mellitus. Methods. - A total of 100 subjects were given both the standard (1.38 mol/L) 75-g oral glucose tolerance test solution and the lower osmolar (0.62 mol/L) 50-g glucose solution. Each test was separated by at least 3 days. Blood samples were drawn at baseline and 30, 60, and 120 minutes after ingestion of each glucose solution. The 1- and 2-hour blood glucose values obtained using the 75-g oral glucose tolerance test beverage were used as the gold standard to diagnose diabetes according to World Health Organization criteria. Results. - Both solutions were shown to have a high sensitivity and specificity for detecting diabetes and impaired glucose tolerance at 30 and 60 minutes. Conclusions. - The physiologic 50-g solution uses less glucose, is highly palatable, and is similar in sweetness and carbohydrate concentration to commonly consumed soda beverages. A larger study including more patients with impaired glucose tolerance will need to be performed to verify our conclusions. The ability to perform high-sensitivity and high-specificity screening for patients with diabetes or impaired glucose tolerance with a single timed blood sample could make mass screening more practical.

UR - http://www.scopus.com/inward/record.url?scp=0029792735&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029792735&partnerID=8YFLogxK

M3 - Article

C2 - 9140289

AN - SCOPUS:0029792735

VL - 120

SP - 842

EP - 846

JO - Archives of Pathology and Laboratory Medicine

JF - Archives of Pathology and Laboratory Medicine

SN - 0003-9985

IS - 9

ER -