Synthetic mesh augmentation of acute and subacute quadriceps tendon repair

Matthew C. Morrey, Jonathan D. Barlow, Matthew P. Abd, Arlen D. Hanssen

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

Quadriceps tendon rupture is an uncommon injury. To date, surgical results have been less than favorable. A novel repair technique that uses Marlex mesh (C R Bard, Murray Hill, New Jersey) has been developed. Use of this repair may allow earlier range of motion and functional restoration of extension. The authors sought to evaluate the technical feasibility, durability, and postoperative function of this repair. This study retrospectively analyzed 8 knees (7 patients) operated on with this technique from 1990 to 2011. Mean follow-up was 9 years. Average age at the time of injury was 69 years. Mean operative time was 130 minutes. No perioperative complications occurred, no patients had clinical evidence of failure, and no patients required subsequent reoperation. Mean flexion at final follow-up was 100. Of the 8 knees, 7 knees had no extensor lag at final follow-up. Marlex mesh augmentation for quadriceps tendon ruptures has promising clinical results, despite significant comorbidities. The results showed that the technique was feasible, with low cost and reasonable operative time. The clinical results were durable, with no intraoperative complications, no re-ruptures, rare extension lag, and good range of motion. Therefore, synthetic mesh augmentation is a feasible option in acute quadriceps tendon ruptures.

Original languageEnglish (US)
Pages (from-to)e9-e13
JournalOrthopedics
Volume39
Issue number1
DOIs
StatePublished - Jan 1 2016

Fingerprint

Tendons
Rupture
Knee
Polypropylenes
Operative Time
Articular Range of Motion
Intraoperative Complications
Wounds and Injuries
Reoperation
Comorbidity
Costs and Cost Analysis

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Cite this

Morrey, M. C., Barlow, J. D., Abd, M. P., & Hanssen, A. D. (2016). Synthetic mesh augmentation of acute and subacute quadriceps tendon repair. Orthopedics, 39(1), e9-e13. https://doi.org/10.3928/01477447-20151218-02

Synthetic mesh augmentation of acute and subacute quadriceps tendon repair. / Morrey, Matthew C.; Barlow, Jonathan D.; Abd, Matthew P.; Hanssen, Arlen D.

In: Orthopedics, Vol. 39, No. 1, 01.01.2016, p. e9-e13.

Research output: Contribution to journalArticle

Morrey, MC, Barlow, JD, Abd, MP & Hanssen, AD 2016, 'Synthetic mesh augmentation of acute and subacute quadriceps tendon repair', Orthopedics, vol. 39, no. 1, pp. e9-e13. https://doi.org/10.3928/01477447-20151218-02
Morrey, Matthew C. ; Barlow, Jonathan D. ; Abd, Matthew P. ; Hanssen, Arlen D. / Synthetic mesh augmentation of acute and subacute quadriceps tendon repair. In: Orthopedics. 2016 ; Vol. 39, No. 1. pp. e9-e13.
@article{ca2c86aad0624e9b8aa04ca0c127710e,
title = "Synthetic mesh augmentation of acute and subacute quadriceps tendon repair",
abstract = "Quadriceps tendon rupture is an uncommon injury. To date, surgical results have been less than favorable. A novel repair technique that uses Marlex mesh (C R Bard, Murray Hill, New Jersey) has been developed. Use of this repair may allow earlier range of motion and functional restoration of extension. The authors sought to evaluate the technical feasibility, durability, and postoperative function of this repair. This study retrospectively analyzed 8 knees (7 patients) operated on with this technique from 1990 to 2011. Mean follow-up was 9 years. Average age at the time of injury was 69 years. Mean operative time was 130 minutes. No perioperative complications occurred, no patients had clinical evidence of failure, and no patients required subsequent reoperation. Mean flexion at final follow-up was 100. Of the 8 knees, 7 knees had no extensor lag at final follow-up. Marlex mesh augmentation for quadriceps tendon ruptures has promising clinical results, despite significant comorbidities. The results showed that the technique was feasible, with low cost and reasonable operative time. The clinical results were durable, with no intraoperative complications, no re-ruptures, rare extension lag, and good range of motion. Therefore, synthetic mesh augmentation is a feasible option in acute quadriceps tendon ruptures.",
author = "Morrey, {Matthew C.} and Barlow, {Jonathan D.} and Abd, {Matthew P.} and Hanssen, {Arlen D.}",
year = "2016",
month = "1",
day = "1",
doi = "10.3928/01477447-20151218-02",
language = "English (US)",
volume = "39",
pages = "e9--e13",
journal = "Orthopedics",
issn = "0147-7447",
publisher = "Slack Incorporated",
number = "1",

}

TY - JOUR

T1 - Synthetic mesh augmentation of acute and subacute quadriceps tendon repair

AU - Morrey, Matthew C.

AU - Barlow, Jonathan D.

AU - Abd, Matthew P.

AU - Hanssen, Arlen D.

PY - 2016/1/1

Y1 - 2016/1/1

N2 - Quadriceps tendon rupture is an uncommon injury. To date, surgical results have been less than favorable. A novel repair technique that uses Marlex mesh (C R Bard, Murray Hill, New Jersey) has been developed. Use of this repair may allow earlier range of motion and functional restoration of extension. The authors sought to evaluate the technical feasibility, durability, and postoperative function of this repair. This study retrospectively analyzed 8 knees (7 patients) operated on with this technique from 1990 to 2011. Mean follow-up was 9 years. Average age at the time of injury was 69 years. Mean operative time was 130 minutes. No perioperative complications occurred, no patients had clinical evidence of failure, and no patients required subsequent reoperation. Mean flexion at final follow-up was 100. Of the 8 knees, 7 knees had no extensor lag at final follow-up. Marlex mesh augmentation for quadriceps tendon ruptures has promising clinical results, despite significant comorbidities. The results showed that the technique was feasible, with low cost and reasonable operative time. The clinical results were durable, with no intraoperative complications, no re-ruptures, rare extension lag, and good range of motion. Therefore, synthetic mesh augmentation is a feasible option in acute quadriceps tendon ruptures.

AB - Quadriceps tendon rupture is an uncommon injury. To date, surgical results have been less than favorable. A novel repair technique that uses Marlex mesh (C R Bard, Murray Hill, New Jersey) has been developed. Use of this repair may allow earlier range of motion and functional restoration of extension. The authors sought to evaluate the technical feasibility, durability, and postoperative function of this repair. This study retrospectively analyzed 8 knees (7 patients) operated on with this technique from 1990 to 2011. Mean follow-up was 9 years. Average age at the time of injury was 69 years. Mean operative time was 130 minutes. No perioperative complications occurred, no patients had clinical evidence of failure, and no patients required subsequent reoperation. Mean flexion at final follow-up was 100. Of the 8 knees, 7 knees had no extensor lag at final follow-up. Marlex mesh augmentation for quadriceps tendon ruptures has promising clinical results, despite significant comorbidities. The results showed that the technique was feasible, with low cost and reasonable operative time. The clinical results were durable, with no intraoperative complications, no re-ruptures, rare extension lag, and good range of motion. Therefore, synthetic mesh augmentation is a feasible option in acute quadriceps tendon ruptures.

UR - http://www.scopus.com/inward/record.url?scp=84958959868&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84958959868&partnerID=8YFLogxK

U2 - 10.3928/01477447-20151218-02

DO - 10.3928/01477447-20151218-02

M3 - Article

C2 - 26709558

AN - SCOPUS:84958959868

VL - 39

SP - e9-e13

JO - Orthopedics

JF - Orthopedics

SN - 0147-7447

IS - 1

ER -