TY - JOUR
T1 - Suture Material as a Factor in the Occurrence of Anastomotic False Aneurysms
T2 - An Analysis of 26 Cases
AU - Starr, David S.
AU - Weatherford, Stephen C.
AU - Lawrie, Gerald M.
AU - Morris, George C.
PY - 1979/4
Y1 - 1979/4
N2 - False aneurysm formation is a well-recognized late complication of prosthetic graft insertion. Despite the fact that other etiologic factors may be involved, the behavior of the suture material remains of central importance. In a retrospective review of 1,330 peripheral vascular cases, we found 26 cases involving a total of 39 false aneurysms, or an incidence of 2% (26/1,330). Twenty-four of these were directly attributable to failure of the monofilament plastic suture or silk suture material. Braided Dacron suture was used in the original anastomosis in another seven cases, and in these instances the false aneurysms were not related to suture failure but were associated with such factors as previous endarterectomy, failure of arterial wall, and chronic hypertension. None of the 39 aneurysms was secondary to infection or trauma. These results emphasize the importance of using a braided, nonabsorbable suture material to ensure the continued integrity of an anastomosis involving prosthetic grafts.
AB - False aneurysm formation is a well-recognized late complication of prosthetic graft insertion. Despite the fact that other etiologic factors may be involved, the behavior of the suture material remains of central importance. In a retrospective review of 1,330 peripheral vascular cases, we found 26 cases involving a total of 39 false aneurysms, or an incidence of 2% (26/1,330). Twenty-four of these were directly attributable to failure of the monofilament plastic suture or silk suture material. Braided Dacron suture was used in the original anastomosis in another seven cases, and in these instances the false aneurysms were not related to suture failure but were associated with such factors as previous endarterectomy, failure of arterial wall, and chronic hypertension. None of the 39 aneurysms was secondary to infection or trauma. These results emphasize the importance of using a braided, nonabsorbable suture material to ensure the continued integrity of an anastomosis involving prosthetic grafts.
UR - http://www.scopus.com/inward/record.url?scp=0018774232&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0018774232&partnerID=8YFLogxK
U2 - 10.1001/archsurg.1979.01370280066009
DO - 10.1001/archsurg.1979.01370280066009
M3 - Article
C2 - 155440
AN - SCOPUS:0018774232
SN - 0004-0010
VL - 114
SP - 412
EP - 415
JO - Archives of Surgery
JF - Archives of Surgery
IS - 4
ER -