Supracondylar-intercondylar fractures of the femur treated with a supracondylar plate and lag screw

J. B. Giles, J. C. DeLee, J. D. Heckman, J. E. Keever

Research output: Contribution to journalArticle

84 Citations (Scopus)

Abstract

Twenty-six patients ranging form nineteen to ninety-two years old underwent rigid internal fixation of supracondylar-intercondylar fractures of the distal end of the femur, using a supracondylar plate and lag screw to achieve two-plane fixation. The congruity of the articular surface of the knee was anatomically restored, as were the mechanical and anatomical axes of the lower extremity. The time to clinical and roentgenographic union averaged four months. There were no non-unions or postoperative infections. The average postoperative range of motion of the knee was 120 degrees. The average length of follow-up was twenty-one months. This series demonstrated the advantages of stable internal fixation using a supracondylar plate and lag screw over other types of fixation.

Original languageEnglish (US)
Pages (from-to)864-870
Number of pages7
JournalJournal of Bone and Joint Surgery - Series A
Volume64
Issue number6
StatePublished - 1982

Fingerprint

Femur
Knee
Articular Range of Motion
Lower Extremity
Joints
Infection

ASJC Scopus subject areas

  • Surgery
  • Orthopedics and Sports Medicine

Cite this

Supracondylar-intercondylar fractures of the femur treated with a supracondylar plate and lag screw. / Giles, J. B.; DeLee, J. C.; Heckman, J. D.; Keever, J. E.

In: Journal of Bone and Joint Surgery - Series A, Vol. 64, No. 6, 1982, p. 864-870.

Research output: Contribution to journalArticle

Giles, J. B. ; DeLee, J. C. ; Heckman, J. D. ; Keever, J. E. / Supracondylar-intercondylar fractures of the femur treated with a supracondylar plate and lag screw. In: Journal of Bone and Joint Surgery - Series A. 1982 ; Vol. 64, No. 6. pp. 864-870.
@article{0d5f3427d5024bb39a89e0966a264ef0,
title = "Supracondylar-intercondylar fractures of the femur treated with a supracondylar plate and lag screw",
abstract = "Twenty-six patients ranging form nineteen to ninety-two years old underwent rigid internal fixation of supracondylar-intercondylar fractures of the distal end of the femur, using a supracondylar plate and lag screw to achieve two-plane fixation. The congruity of the articular surface of the knee was anatomically restored, as were the mechanical and anatomical axes of the lower extremity. The time to clinical and roentgenographic union averaged four months. There were no non-unions or postoperative infections. The average postoperative range of motion of the knee was 120 degrees. The average length of follow-up was twenty-one months. This series demonstrated the advantages of stable internal fixation using a supracondylar plate and lag screw over other types of fixation.",
author = "Giles, {J. B.} and DeLee, {J. C.} and Heckman, {J. D.} and Keever, {J. E.}",
year = "1982",
language = "English (US)",
volume = "64",
pages = "864--870",
journal = "Journal of Bone and Joint Surgery - American Volume",
issn = "0021-9355",
publisher = "Journal of Bone and Joint Surgery Inc.",
number = "6",

}

TY - JOUR

T1 - Supracondylar-intercondylar fractures of the femur treated with a supracondylar plate and lag screw

AU - Giles, J. B.

AU - DeLee, J. C.

AU - Heckman, J. D.

AU - Keever, J. E.

PY - 1982

Y1 - 1982

N2 - Twenty-six patients ranging form nineteen to ninety-two years old underwent rigid internal fixation of supracondylar-intercondylar fractures of the distal end of the femur, using a supracondylar plate and lag screw to achieve two-plane fixation. The congruity of the articular surface of the knee was anatomically restored, as were the mechanical and anatomical axes of the lower extremity. The time to clinical and roentgenographic union averaged four months. There were no non-unions or postoperative infections. The average postoperative range of motion of the knee was 120 degrees. The average length of follow-up was twenty-one months. This series demonstrated the advantages of stable internal fixation using a supracondylar plate and lag screw over other types of fixation.

AB - Twenty-six patients ranging form nineteen to ninety-two years old underwent rigid internal fixation of supracondylar-intercondylar fractures of the distal end of the femur, using a supracondylar plate and lag screw to achieve two-plane fixation. The congruity of the articular surface of the knee was anatomically restored, as were the mechanical and anatomical axes of the lower extremity. The time to clinical and roentgenographic union averaged four months. There were no non-unions or postoperative infections. The average postoperative range of motion of the knee was 120 degrees. The average length of follow-up was twenty-one months. This series demonstrated the advantages of stable internal fixation using a supracondylar plate and lag screw over other types of fixation.

UR - http://www.scopus.com/inward/record.url?scp=0019988303&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0019988303&partnerID=8YFLogxK

M3 - Article

C2 - 7085713

AN - SCOPUS:0019988303

VL - 64

SP - 864

EP - 870

JO - Journal of Bone and Joint Surgery - American Volume

JF - Journal of Bone and Joint Surgery - American Volume

SN - 0021-9355

IS - 6

ER -