SU‐GG‐T‐421: Radiobiological Optimization of Breast Cancer Radiotherapy Taking Into Account Patient Positioning, Breathing and Radiation Pneumonitis Scoring

S. Hyodynmaa, P. Mavroidis, B. Ferreira, S. Axelsson, N. Papanikolaou, B. Lind

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: Significant discrepancies in dose delivery can contribute to underdosage of the tumor or overdosage of normal tissue. To study the impact of patient positioning and internal organ motion in breast cancer radiotherapy, the setup and breathing uncertainties characterizing three different irradiation techniques are employed. Method and Materials: Fifteen breast cancer patients (5 resected with negative nodes (R−), 5 resected with positive nodes (R+) and 5 ablated), who were treated with three different irradiation techniques are examined. The positioning uncertainties in the anteroposterior (AP) and the craniocaudal (CC) directions are approximated by Gaussian distributions and breathing is assumed to be linear. The combined frequency distributions of the positioning and breathing distributions are obtained by convolution. The three radiation techniques are compared by using the complication‐free tumor control probability, P+ and the biologically effective uniform dose (BEUD). Results: For the R− case, at the optimum dose levels of the two dose distributions, the P+ values are 97.9% and 97.3%, respectively. The respective total control probabilities, PB are 99.3% and 99.1%, whereas the corresponding total complication probabilities, PI are 1.4% and 1.8%. For the R+ case, the P+ values are 94.2% and 93.0%, respectively. The PB values are 97.5% and 96.3%, whereas the PI values are 3.3% and 3.3%. For the Ablation case, the P+ values are 96.9% and 89.4%, respectively. The PB values are 99.0% and 96.5%, whereas the PI values are 2.1% and 7.2%. In this case, for lung radiation pneumonitis Grade 1–2 the P+ values would change to 69.3% and 37.7%, respectively. Conclusion: The combined effects of positioning uncertainties and breathing motion can introduce a significant deviation between the planned and delivered dose distributions to the lung in breast cancer radiotherapy. This inaccuracy in the delivered dose may lead to a significant underestimation of the expected lung complications.

Original languageEnglish (US)
Pages (from-to)2821
Number of pages1
JournalMedical physics
Volume35
Issue number6
DOIs
StatePublished - Jun 2008
Externally publishedYes

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'SU‐GG‐T‐421: Radiobiological Optimization of Breast Cancer Radiotherapy Taking Into Account Patient Positioning, Breathing and Radiation Pneumonitis Scoring'. Together they form a unique fingerprint.

Cite this