Spin-echo fMRI in humans using high spatial resolutions and high magnetic fields

Essa Yacoub, Timothy Q. Duong, Pierre Francois Van De Moortele, Martin Lindquist, Gregor Adriany, Seong Gi Kim, Kâmil Uǧurbil, Xiaoping Hu

Research output: Contribution to journalArticle

218 Citations (Scopus)

Abstract

The Hahn spin-echo (HSE)-based BOLD effect at high magnetic fields is expected to provide functional images that originate exclusively from the microvasculature. The blood contribution that dominates HSE BOLD contrast at low magnetic fields (e.g., 1.5 T), and degrades specificity, is highly attenuated at high fields because the apparent T2 of venous blood in an HSE experiment decreases quadratically with increasing magnetic field. In contrast, the HSE BOLD contrast is believed to arise from the microvasculature and increase supralinearly with the magnetic field strength. In this work we report the results of detailed and quantitative evaluations of HSE BOLD signal changes for functional imaging in the human visual cortex at 4 and 7 T. This study used high spatial resolution, afforded by the increased signal-to-noise ratio (SNR) of higher field strengths and surface coils, to avoid partial volume effects (PVEs), and demonstrated increased contrast-to-noise ratio (CNR) and spatial specificity at the higher field strengths. The HSE BOLD signal changes induced by visual stimulation were predominantly linearly dependent on the echo time (TE). They increased in magnitude almost quadratically in going from 4 to 7 T when the blood contribution was suppressed using Stejskal-Tanner gradients that suppress signals from the blood due to its inhomogeneous flow and higher diffusion constant relative to tissue. The HSE signal changes at 7 T were modeled accurately using a vascular volume of 1.5%, in agreement with the capillary volume of gray matter. Furthermore, high-resolution acquisitions indicate that CNR increased with voxel sizes < 1 mm3 due to diminishing white matter or cerebrospinal fluidspace vs. gray matter PVEs. It was concluded that the high-field HSE functional MRI (fMRI) signals originated largely from the capillaries, and that the magnitude of the signal changes associated with brain function reached sufficiently high levels at 7 T to make it a useful approach for mapping on the millimeter to submillimeter spatial scale.

Original languageEnglish (US)
Pages (from-to)655-664
Number of pages10
JournalMagnetic Resonance in Medicine
Volume49
Issue number4
DOIs
StatePublished - Apr 1 2003
Externally publishedYes

Fingerprint

Magnetic Fields
Magnetic Resonance Imaging
Microvessels
Noise
Photic Stimulation
Signal-To-Noise Ratio
Visual Cortex
Blood Vessels
Brain
Gray Matter

Keywords

  • BOLD
  • Brain
  • Cerebral function
  • fMRI
  • Functional mapping
  • High fields
  • Spin echo

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Yacoub, E., Duong, T. Q., Van De Moortele, P. F., Lindquist, M., Adriany, G., Kim, S. G., ... Hu, X. (2003). Spin-echo fMRI in humans using high spatial resolutions and high magnetic fields. Magnetic Resonance in Medicine, 49(4), 655-664. https://doi.org/10.1002/mrm.10433

Spin-echo fMRI in humans using high spatial resolutions and high magnetic fields. / Yacoub, Essa; Duong, Timothy Q.; Van De Moortele, Pierre Francois; Lindquist, Martin; Adriany, Gregor; Kim, Seong Gi; Uǧurbil, Kâmil; Hu, Xiaoping.

In: Magnetic Resonance in Medicine, Vol. 49, No. 4, 01.04.2003, p. 655-664.

Research output: Contribution to journalArticle

Yacoub, E, Duong, TQ, Van De Moortele, PF, Lindquist, M, Adriany, G, Kim, SG, Uǧurbil, K & Hu, X 2003, 'Spin-echo fMRI in humans using high spatial resolutions and high magnetic fields', Magnetic Resonance in Medicine, vol. 49, no. 4, pp. 655-664. https://doi.org/10.1002/mrm.10433
Yacoub E, Duong TQ, Van De Moortele PF, Lindquist M, Adriany G, Kim SG et al. Spin-echo fMRI in humans using high spatial resolutions and high magnetic fields. Magnetic Resonance in Medicine. 2003 Apr 1;49(4):655-664. https://doi.org/10.1002/mrm.10433
Yacoub, Essa ; Duong, Timothy Q. ; Van De Moortele, Pierre Francois ; Lindquist, Martin ; Adriany, Gregor ; Kim, Seong Gi ; Uǧurbil, Kâmil ; Hu, Xiaoping. / Spin-echo fMRI in humans using high spatial resolutions and high magnetic fields. In: Magnetic Resonance in Medicine. 2003 ; Vol. 49, No. 4. pp. 655-664.
@article{478af87e0a8b42f697b0d113a818ffbb,
title = "Spin-echo fMRI in humans using high spatial resolutions and high magnetic fields",
abstract = "The Hahn spin-echo (HSE)-based BOLD effect at high magnetic fields is expected to provide functional images that originate exclusively from the microvasculature. The blood contribution that dominates HSE BOLD contrast at low magnetic fields (e.g., 1.5 T), and degrades specificity, is highly attenuated at high fields because the apparent T2 of venous blood in an HSE experiment decreases quadratically with increasing magnetic field. In contrast, the HSE BOLD contrast is believed to arise from the microvasculature and increase supralinearly with the magnetic field strength. In this work we report the results of detailed and quantitative evaluations of HSE BOLD signal changes for functional imaging in the human visual cortex at 4 and 7 T. This study used high spatial resolution, afforded by the increased signal-to-noise ratio (SNR) of higher field strengths and surface coils, to avoid partial volume effects (PVEs), and demonstrated increased contrast-to-noise ratio (CNR) and spatial specificity at the higher field strengths. The HSE BOLD signal changes induced by visual stimulation were predominantly linearly dependent on the echo time (TE). They increased in magnitude almost quadratically in going from 4 to 7 T when the blood contribution was suppressed using Stejskal-Tanner gradients that suppress signals from the blood due to its inhomogeneous flow and higher diffusion constant relative to tissue. The HSE signal changes at 7 T were modeled accurately using a vascular volume of 1.5{\%}, in agreement with the capillary volume of gray matter. Furthermore, high-resolution acquisitions indicate that CNR increased with voxel sizes < 1 mm3 due to diminishing white matter or cerebrospinal fluidspace vs. gray matter PVEs. It was concluded that the high-field HSE functional MRI (fMRI) signals originated largely from the capillaries, and that the magnitude of the signal changes associated with brain function reached sufficiently high levels at 7 T to make it a useful approach for mapping on the millimeter to submillimeter spatial scale.",
keywords = "BOLD, Brain, Cerebral function, fMRI, Functional mapping, High fields, Spin echo",
author = "Essa Yacoub and Duong, {Timothy Q.} and {Van De Moortele}, {Pierre Francois} and Martin Lindquist and Gregor Adriany and Kim, {Seong Gi} and K{\^a}mil Uǧurbil and Xiaoping Hu",
year = "2003",
month = "4",
day = "1",
doi = "10.1002/mrm.10433",
language = "English (US)",
volume = "49",
pages = "655--664",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "4",

}

TY - JOUR

T1 - Spin-echo fMRI in humans using high spatial resolutions and high magnetic fields

AU - Yacoub, Essa

AU - Duong, Timothy Q.

AU - Van De Moortele, Pierre Francois

AU - Lindquist, Martin

AU - Adriany, Gregor

AU - Kim, Seong Gi

AU - Uǧurbil, Kâmil

AU - Hu, Xiaoping

PY - 2003/4/1

Y1 - 2003/4/1

N2 - The Hahn spin-echo (HSE)-based BOLD effect at high magnetic fields is expected to provide functional images that originate exclusively from the microvasculature. The blood contribution that dominates HSE BOLD contrast at low magnetic fields (e.g., 1.5 T), and degrades specificity, is highly attenuated at high fields because the apparent T2 of venous blood in an HSE experiment decreases quadratically with increasing magnetic field. In contrast, the HSE BOLD contrast is believed to arise from the microvasculature and increase supralinearly with the magnetic field strength. In this work we report the results of detailed and quantitative evaluations of HSE BOLD signal changes for functional imaging in the human visual cortex at 4 and 7 T. This study used high spatial resolution, afforded by the increased signal-to-noise ratio (SNR) of higher field strengths and surface coils, to avoid partial volume effects (PVEs), and demonstrated increased contrast-to-noise ratio (CNR) and spatial specificity at the higher field strengths. The HSE BOLD signal changes induced by visual stimulation were predominantly linearly dependent on the echo time (TE). They increased in magnitude almost quadratically in going from 4 to 7 T when the blood contribution was suppressed using Stejskal-Tanner gradients that suppress signals from the blood due to its inhomogeneous flow and higher diffusion constant relative to tissue. The HSE signal changes at 7 T were modeled accurately using a vascular volume of 1.5%, in agreement with the capillary volume of gray matter. Furthermore, high-resolution acquisitions indicate that CNR increased with voxel sizes < 1 mm3 due to diminishing white matter or cerebrospinal fluidspace vs. gray matter PVEs. It was concluded that the high-field HSE functional MRI (fMRI) signals originated largely from the capillaries, and that the magnitude of the signal changes associated with brain function reached sufficiently high levels at 7 T to make it a useful approach for mapping on the millimeter to submillimeter spatial scale.

AB - The Hahn spin-echo (HSE)-based BOLD effect at high magnetic fields is expected to provide functional images that originate exclusively from the microvasculature. The blood contribution that dominates HSE BOLD contrast at low magnetic fields (e.g., 1.5 T), and degrades specificity, is highly attenuated at high fields because the apparent T2 of venous blood in an HSE experiment decreases quadratically with increasing magnetic field. In contrast, the HSE BOLD contrast is believed to arise from the microvasculature and increase supralinearly with the magnetic field strength. In this work we report the results of detailed and quantitative evaluations of HSE BOLD signal changes for functional imaging in the human visual cortex at 4 and 7 T. This study used high spatial resolution, afforded by the increased signal-to-noise ratio (SNR) of higher field strengths and surface coils, to avoid partial volume effects (PVEs), and demonstrated increased contrast-to-noise ratio (CNR) and spatial specificity at the higher field strengths. The HSE BOLD signal changes induced by visual stimulation were predominantly linearly dependent on the echo time (TE). They increased in magnitude almost quadratically in going from 4 to 7 T when the blood contribution was suppressed using Stejskal-Tanner gradients that suppress signals from the blood due to its inhomogeneous flow and higher diffusion constant relative to tissue. The HSE signal changes at 7 T were modeled accurately using a vascular volume of 1.5%, in agreement with the capillary volume of gray matter. Furthermore, high-resolution acquisitions indicate that CNR increased with voxel sizes < 1 mm3 due to diminishing white matter or cerebrospinal fluidspace vs. gray matter PVEs. It was concluded that the high-field HSE functional MRI (fMRI) signals originated largely from the capillaries, and that the magnitude of the signal changes associated with brain function reached sufficiently high levels at 7 T to make it a useful approach for mapping on the millimeter to submillimeter spatial scale.

KW - BOLD

KW - Brain

KW - Cerebral function

KW - fMRI

KW - Functional mapping

KW - High fields

KW - Spin echo

UR - http://www.scopus.com/inward/record.url?scp=0037381051&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0037381051&partnerID=8YFLogxK

U2 - 10.1002/mrm.10433

DO - 10.1002/mrm.10433

M3 - Article

C2 - 12652536

AN - SCOPUS:0037381051

VL - 49

SP - 655

EP - 664

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 4

ER -