TY - JOUR
T1 - Sonographically observed echogenic response during intaoperative radiofrequency ablation of cirrhotic livers
T2 - Pathologic correlation
AU - Leyendecker, John R.
AU - Dodd, Gerald D.
AU - Halff, Glenn A.
AU - McCoy, Victor A.
AU - Napier, Dacia H.
AU - Hubbard, Linda G.
AU - Chintapalli, Kedar N.
AU - Chopra, Shailendra
AU - Washburn, W. Kenneth
AU - Esterl, Robert M.
AU - Cigarroa, Francisco G.
AU - Kohlmeier, Ruth E.
AU - Sharkey, Francis E.
PY - 2002
Y1 - 2002
N2 - OBJECTIVE. We performed a study to determine the correlation between the diameter of the echogenic response observed with intraoperative sonography during radiofrequency ablation of the cirrhotic liver and the mean diameter of tissue necrosis. SUBJECTS AND METHODS. A total of 22 intraoperative radiofrequency ablations were created in 11 cirrhotic livers. The largest diameter of the sonographically observed echogenic response surrounding and perpendicular to the radiofrequency probe was measured. The subsequent zone of necrosis observed at pathology in the hepatectomy specimens after liver transplantation was measured in three planes and compared with the measured diameter of the echogenic response. RESULTS. During all except three ablations, a hyperechoic region was visualized surrounding the radiofrequency probe. The diameter of the echogenic response correlated significantly with the mean diameter of necrosis (correlation coefficient, 0.84). However, the echogenic response overestimated the minimal diameter of necrosis (mean difference, 0.8 ± 0.4 cm) in 18 of 22 ablations and underestimated the maximum diameter of necrosis (mean difference, 0.9 ± 0.8 cm) in 16 of 22 ablations. CONCLUSION. The diameter of the echogenic response observed with intraoperative sonography during radiofrequency ablation of the cirrhotic liver correlates closely with the mean diameter of the subsequent area of tissue necrosis. However, the solitary diameter of the echogenic response as measured in our study was often greater than the smallest diameter and less than the largest diameter of the area of tissue necrosis. Therefore, the echogenic response associated with radiofrequency ablation of the cirrhotic liver should be viewed only as a rough approximation of the area of induced tissue necrosis; the final assessment of the adequacy of ablation should be deferred to an alternative imaging technique.
AB - OBJECTIVE. We performed a study to determine the correlation between the diameter of the echogenic response observed with intraoperative sonography during radiofrequency ablation of the cirrhotic liver and the mean diameter of tissue necrosis. SUBJECTS AND METHODS. A total of 22 intraoperative radiofrequency ablations were created in 11 cirrhotic livers. The largest diameter of the sonographically observed echogenic response surrounding and perpendicular to the radiofrequency probe was measured. The subsequent zone of necrosis observed at pathology in the hepatectomy specimens after liver transplantation was measured in three planes and compared with the measured diameter of the echogenic response. RESULTS. During all except three ablations, a hyperechoic region was visualized surrounding the radiofrequency probe. The diameter of the echogenic response correlated significantly with the mean diameter of necrosis (correlation coefficient, 0.84). However, the echogenic response overestimated the minimal diameter of necrosis (mean difference, 0.8 ± 0.4 cm) in 18 of 22 ablations and underestimated the maximum diameter of necrosis (mean difference, 0.9 ± 0.8 cm) in 16 of 22 ablations. CONCLUSION. The diameter of the echogenic response observed with intraoperative sonography during radiofrequency ablation of the cirrhotic liver correlates closely with the mean diameter of the subsequent area of tissue necrosis. However, the solitary diameter of the echogenic response as measured in our study was often greater than the smallest diameter and less than the largest diameter of the area of tissue necrosis. Therefore, the echogenic response associated with radiofrequency ablation of the cirrhotic liver should be viewed only as a rough approximation of the area of induced tissue necrosis; the final assessment of the adequacy of ablation should be deferred to an alternative imaging technique.
UR - http://www.scopus.com/inward/record.url?scp=0036103427&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0036103427&partnerID=8YFLogxK
U2 - 10.2214/ajr.178.5.1781147
DO - 10.2214/ajr.178.5.1781147
M3 - Article
C2 - 11959720
AN - SCOPUS:0036103427
SN - 0361-803X
VL - 178
SP - 1147
EP - 1151
JO - American Journal of Roentgenology
JF - American Journal of Roentgenology
IS - 5
ER -