TY - JOUR
T1 - Short segment spinal instrumentation with index vertebra pedicle screw placement for pathologies involving the anterior and middle vertebral column is as effective as long segment stabilization with cage reconstruction
T2 - A biomechanical study
AU - Bartanusz, Viktor
AU - Harris, Jonathan
AU - Moldavsky, Mark
AU - Cai, Yiwei
AU - Bucklen, Brandon
PY - 2015/11/1
Y1 - 2015/11/1
N2 - Study Design. An in vitro, cadaveric biomechanical study. Objective. The aim of the present study was to compare single-segment posterior instrumentation and fracture-level screws with single/multilevel posterior fixation and corpectomy in a simulated, unstable burst fracture model. Summary of Background Data. The optimal extent of instrumentation for surgical cases of non-neoplastic vertebral body pathologies remains uncertain. Although several clinical studies demonstrate advantages of short segment instrumentation with index-level screws over more extensive corpectomy and anterior-posterior techniques, a comprehensive biomechanical comparison of these techniques is currently lacking. Methods. Six bovine spines (T11-L5) were tested in flexion, extension, lateral bending (LB), and axial rotation (AR) following simulated burst fracture at L2. Posterior instrumentation included 1 level above/below (1LF) and 2 levels above/below fracture level (2LF), intermediate or index screws at fracture level (FF), and cross-connectors above/below fracture level (CC). Anterior corpectomy devices included expandable corpectomy spacers with/without integrated screws, ACDi and ACD, respectively FORTIFY-Integrated/FORTIFY; Globus Medical, Inc., PA. Constructs were tested in the following order: (1) Intact; (2) 1LF; (3) 1LF and CC; (4) 1LF and FF; (5) 1LF, CC, and FF; (6) 2LF; (7) 2LF and CC; (8) 2LF and FF; (9) 2LF, CC, and FF; (10) 2LF and ACD; (11) 2LF, ACD, and CC; (12) 1LF and ACDi; (13) 1LF, ACDi, and CC. Results. During flexion, all constructs except 1LF reduced motion relative to intact (P≤0.05). Anterior support was most stable, but no differences were found between constructs (P≥0.05). Every construct reduced motion in extension, though no differences were found between constructs and intact (P≥0.05). During LB, all constructs reduced motion relative to intact (P≤0.05); 2LF constructs further reduced motion (P≤0.05). No construct returned AR motion to intact, with significant increases in 1LF and ACDi, 2LF and ACD, and 2LF, ACD, and CC (P≤0.05). Cross-connectors and fracture screws reinforced each other in posterior-only constructs, providing maximum stability (P≥0.05). Conclusions. This biomechanical comparison study found no significant superiority of combined anterior-posterior constructs over short segment fracture screw fixation, only multilevel posterior instrumentation with and without anterior support, providing increased stability in LB. Biomechanical equivalency suggests that short segment fracture screw intervention may provide appropriate stabilization for non-neoplastic pathologies involving the anterior and middle vertebral columns.
AB - Study Design. An in vitro, cadaveric biomechanical study. Objective. The aim of the present study was to compare single-segment posterior instrumentation and fracture-level screws with single/multilevel posterior fixation and corpectomy in a simulated, unstable burst fracture model. Summary of Background Data. The optimal extent of instrumentation for surgical cases of non-neoplastic vertebral body pathologies remains uncertain. Although several clinical studies demonstrate advantages of short segment instrumentation with index-level screws over more extensive corpectomy and anterior-posterior techniques, a comprehensive biomechanical comparison of these techniques is currently lacking. Methods. Six bovine spines (T11-L5) were tested in flexion, extension, lateral bending (LB), and axial rotation (AR) following simulated burst fracture at L2. Posterior instrumentation included 1 level above/below (1LF) and 2 levels above/below fracture level (2LF), intermediate or index screws at fracture level (FF), and cross-connectors above/below fracture level (CC). Anterior corpectomy devices included expandable corpectomy spacers with/without integrated screws, ACDi and ACD, respectively FORTIFY-Integrated/FORTIFY; Globus Medical, Inc., PA. Constructs were tested in the following order: (1) Intact; (2) 1LF; (3) 1LF and CC; (4) 1LF and FF; (5) 1LF, CC, and FF; (6) 2LF; (7) 2LF and CC; (8) 2LF and FF; (9) 2LF, CC, and FF; (10) 2LF and ACD; (11) 2LF, ACD, and CC; (12) 1LF and ACDi; (13) 1LF, ACDi, and CC. Results. During flexion, all constructs except 1LF reduced motion relative to intact (P≤0.05). Anterior support was most stable, but no differences were found between constructs (P≥0.05). Every construct reduced motion in extension, though no differences were found between constructs and intact (P≥0.05). During LB, all constructs reduced motion relative to intact (P≤0.05); 2LF constructs further reduced motion (P≤0.05). No construct returned AR motion to intact, with significant increases in 1LF and ACDi, 2LF and ACD, and 2LF, ACD, and CC (P≤0.05). Cross-connectors and fracture screws reinforced each other in posterior-only constructs, providing maximum stability (P≥0.05). Conclusions. This biomechanical comparison study found no significant superiority of combined anterior-posterior constructs over short segment fracture screw fixation, only multilevel posterior instrumentation with and without anterior support, providing increased stability in LB. Biomechanical equivalency suggests that short segment fracture screw intervention may provide appropriate stabilization for non-neoplastic pathologies involving the anterior and middle vertebral columns.
KW - cadaveric biomechanics
KW - index pedicle screws
KW - short segment posterior instrumentation
KW - unstable burst fracture
UR - http://www.scopus.com/inward/record.url?scp=84946422860&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84946422860&partnerID=8YFLogxK
U2 - 10.1097/BRS.0000000000001130
DO - 10.1097/BRS.0000000000001130
M3 - Article
C2 - 26536447
AN - SCOPUS:84946422860
VL - 40
SP - 1729
EP - 1736
JO - Spine
JF - Spine
SN - 0362-2436
IS - 22
ER -