TY - JOUR
T1 - Response Surface Methodology As a New Approach for Finding Optimal MALDI Matrix Spraying Parameters for Mass Spectrometry Imaging
AU - Veličković, Dušan
AU - Zhang, Guanshi
AU - Bezbradica, Dejan
AU - Bhattacharjee, Arunima
AU - Paša-Tolić, Ljiljana
AU - Sharma, Kumar
AU - Alexandrov, Theodore
AU - Anderton, Christopher R.
N1 - Publisher Copyright:
© 2020 Springer New York LLC. All rights reserved.
PY - 2020/3/4
Y1 - 2020/3/4
N2 - Automated spraying devices have become ubiquitous in laboratories employing matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI), in part because they permit control of a number of matrix application parameters that can easily be reproduced for intra- and interlaboratory studies. Determining the optimal parameters for MALDI matrix application, such as temperature, flow rate, spraying velocity, number of spraying cycles, and solvent composition for matrix application, is critical for obtaining high-quality MALDI-MSI data. However, there are no established approaches for optimizing these multiple parameters simultaneously. Instead optimization is performed iteratively (i.e., one parameter at a time), which is time-consuming and can lead to overall nonoptimal settings. In this report, we demonstrate the use a novel experimental design and the response surface methodology to optimize five parameters of MALDI matrix application using a robotic sprayer. Thirty-two combinations of MALDI matrix spraying conditions were tested, which allowed us to elucidate relationships between each of the application parameters as determined by MALDI-MS (specifically, using a 15 T Fourier transform ion cyclotron resonance mass spectrometer). As such, we were able to determine the optimal automated spraying parameters that minimized signal delocalization and enabled high MALDI sensitivity. We envision this optimization strategy can be utilized for other matrix application approaches and MALDI-MSI analyses of other molecular classes and tissue types.
AB - Automated spraying devices have become ubiquitous in laboratories employing matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI), in part because they permit control of a number of matrix application parameters that can easily be reproduced for intra- and interlaboratory studies. Determining the optimal parameters for MALDI matrix application, such as temperature, flow rate, spraying velocity, number of spraying cycles, and solvent composition for matrix application, is critical for obtaining high-quality MALDI-MSI data. However, there are no established approaches for optimizing these multiple parameters simultaneously. Instead optimization is performed iteratively (i.e., one parameter at a time), which is time-consuming and can lead to overall nonoptimal settings. In this report, we demonstrate the use a novel experimental design and the response surface methodology to optimize five parameters of MALDI matrix application using a robotic sprayer. Thirty-two combinations of MALDI matrix spraying conditions were tested, which allowed us to elucidate relationships between each of the application parameters as determined by MALDI-MS (specifically, using a 15 T Fourier transform ion cyclotron resonance mass spectrometer). As such, we were able to determine the optimal automated spraying parameters that minimized signal delocalization and enabled high MALDI sensitivity. We envision this optimization strategy can be utilized for other matrix application approaches and MALDI-MSI analyses of other molecular classes and tissue types.
KW - METASPACE
KW - delocalization quantification
KW - experimental design
KW - human biopsy
KW - molecular annotation
UR - http://www.scopus.com/inward/record.url?scp=85081041220&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85081041220&partnerID=8YFLogxK
U2 - 10.1021/jasms.9b00074
DO - 10.1021/jasms.9b00074
M3 - Article
C2 - 32126772
AN - SCOPUS:85081041220
SN - 1044-0305
VL - 31
SP - 508
EP - 516
JO - Journal of the American Society for Mass Spectrometry
JF - Journal of the American Society for Mass Spectrometry
IS - 3
ER -