Replacement of a fractured unilateral removable partial denture with a nonrigid fixed prosthesis

A clinical report

David M. Bohnenkamp

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Replacement of a fractured unilateral RPD with a five-unit nonrigid FPD was described in this clinical report, with the following advantages. (1) Swallowing or aspiration of a unilateral removable prothesis will be avoided. (2) Fracture of solid metal connectors is diminished. (3) Metal-ceramic retainers and pontics will improve the patient's esthetic and functional demands.

Original languageEnglish (US)
Pages (from-to)591-593
Number of pages3
JournalJournal of Prosthetic Dentistry
Volume75
Issue number6
StatePublished - 1996
Externally publishedYes

Fingerprint

Removable Partial Denture
Prostheses and Implants
Metals
Fixed Partial Denture
Ceramics
Deglutition
Esthetics
Aspirations (Psychology)

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Replacement of a fractured unilateral removable partial denture with a nonrigid fixed prosthesis : A clinical report. / Bohnenkamp, David M.

In: Journal of Prosthetic Dentistry, Vol. 75, No. 6, 1996, p. 591-593.

Research output: Contribution to journalArticle

@article{ace19cffe41e4618b820f9e511ae6168,
title = "Replacement of a fractured unilateral removable partial denture with a nonrigid fixed prosthesis: A clinical report",
abstract = "Replacement of a fractured unilateral RPD with a five-unit nonrigid FPD was described in this clinical report, with the following advantages. (1) Swallowing or aspiration of a unilateral removable prothesis will be avoided. (2) Fracture of solid metal connectors is diminished. (3) Metal-ceramic retainers and pontics will improve the patient's esthetic and functional demands.",
author = "Bohnenkamp, {David M.}",
year = "1996",
language = "English (US)",
volume = "75",
pages = "591--593",
journal = "Journal of Prosthetic Dentistry",
issn = "0022-3913",
publisher = "Mosby Inc.",
number = "6",

}

TY - JOUR

T1 - Replacement of a fractured unilateral removable partial denture with a nonrigid fixed prosthesis

T2 - A clinical report

AU - Bohnenkamp, David M.

PY - 1996

Y1 - 1996

N2 - Replacement of a fractured unilateral RPD with a five-unit nonrigid FPD was described in this clinical report, with the following advantages. (1) Swallowing or aspiration of a unilateral removable prothesis will be avoided. (2) Fracture of solid metal connectors is diminished. (3) Metal-ceramic retainers and pontics will improve the patient's esthetic and functional demands.

AB - Replacement of a fractured unilateral RPD with a five-unit nonrigid FPD was described in this clinical report, with the following advantages. (1) Swallowing or aspiration of a unilateral removable prothesis will be avoided. (2) Fracture of solid metal connectors is diminished. (3) Metal-ceramic retainers and pontics will improve the patient's esthetic and functional demands.

UR - http://www.scopus.com/inward/record.url?scp=0030159683&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030159683&partnerID=8YFLogxK

M3 - Article

VL - 75

SP - 591

EP - 593

JO - Journal of Prosthetic Dentistry

JF - Journal of Prosthetic Dentistry

SN - 0022-3913

IS - 6

ER -