Pulse wave analysis of the aortic pressure waveform in severe left ventricular systolic dysfunction

  • Scott J. Denardo
  • , Ramavathi Nandyala
  • , Gregory L. Freeman
  • , Gary L. Pierce
  • , Wilmer W. Nichols

Research output: Contribution to journalArticlepeer-review

Abstract

Background:The effect of moderate left ventricular systolic dysfunction (LVSD) on ventricular/vascular coupling and the aortic pressure waveform (AoPW) has been well described, but the effect of severe LVSD has not. Methods and Results:We used noninvasive, high-fidelity tonometry of the radial artery and a mathematical transfer function to generate the AoPW in 25 treated patients with LVSD (mean LV ejection fraction, 24±8.8%; range, 11% to 40%; 21 patients <30%). Pulse wave analysis of the AoPW was used to characterize ventricular/vascular coupling and compared with pulse wave analysis performed in 25 normal subjects matched for age, gender, height, body mass index, and heart rate. Measurements obtained using pulse wave analysis in LVSD patients indicated features of poor LV stroke performance and also reduced indices of arterial stiffness: increased travel time of the pressure wave (147 ± 10 ms versus 132±21 ms; P<0.001); decreased systolic duration of reflected wave (134±24 ms versus 167±26 ms; P<0.001); ejection duration (277±22 ms versus 299±25 ms; P<0.008); percent systolic duration (32±5.3% versus 35±4.0%; P<0.02); aortic systolic pressure (100±16 mmHg versus 121 ±16 mmHg; P<0.001); unaugmented pressure (24±6.3 mmHg versus 32±6.4 mmHg; P<0.001); augmented pressure (4.8±3.1 mmHg versus 9.6±4.5 mmHg; P<0.001); pulse pressure (28±7.4 mmHg versus 42±9.5 mmHg; P<0.001); augmentation index (12±6.6% versus 23±7.6%; P<0.006); wasted LV effort (5.3±2.8×102 dyne sec/cm2 versus 17±10×102 dyne sec/cm 2; P<0.001); systolic pressure time index (17±4. 1×102 mmHg-sec/min versus 23±4.2×102 mmHgsec/min; P<0.001); and pressure systolic area (383±121 mmHg sec/min versus 666±150 mmHg sec/min; P<0.001). Conclusions:Severe LVSD causes measurable changes in the AoPW. Standardization of AoPW findings in LVSD patients may allow for the clinical use of radial artery pulse wave analysis to noninvasively determine the severity of dysfunction and aid in logical therapy.

Original languageEnglish (US)
Pages (from-to)149-156
Number of pages8
JournalCirculation: Heart Failure
Volume3
Issue number1
DOIs
StatePublished - Jan 2010

Keywords

  • Aortic pressure waveform
  • Hemodynamics
  • Left ventricular dysfunction
  • Ventricular/vascular coupling

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Pulse wave analysis of the aortic pressure waveform in severe left ventricular systolic dysfunction'. Together they form a unique fingerprint.

Cite this