T1 - Preliminary investigation
T2 - Evaluation of a new vascular occlusion device
AU - Nazarian, Gwen K.
AU - Qian, Zhong
AU - Vlodaver, Zeev
AU - Pozza, Christopher H.
AU - Castaneda-Zúniga, Wilfrido R.
AU - Hunter, David W.
AU - Amplatz, Kurt
PY - 1993/12
Y1 - 1993/12
N2 - RATIONALE AND OBJECTIVES. A new vascular occlusion device was tested in canine femoral and iliac arteries and in an animal model of a patent ductus arteriosus (PDA). METHODS. Four variations of the vascular plug were placed into 18 iliac or femoral arteries of 17 mongrel dogs. Follow-up angiography was performed 1 hour and, if necessary, 2 hours after placement in all animals, 14 of which were then killed. Three dogs were followed angiographically for 2 weeks to 3 months. The “butterfly” plug was then tested in a canine model of a PDA. RESULTS. All plugs contained thrombi, and 12 of the 18 devices caused complete or nearly complete vascular occlusion within 2 hours. In one dog, one vascular plug had eroded through the vessel wall at 3 months without clinical sequelae. Successful PDA occlusion was achieved in 1 or 2 days in 6 of 8 dogs. Three misplacements occurred, one of which resulted in death. DISCUSSION. The balloon-expandable vascular plug appears to be a promising device for occlusion of blood vessels. Migration has not been observed once the device is placed, thus, sizing of the device appears less critical than with coils. However, modification of the delivery system and considerably more experience with the device are necessary to reduce the risk of misplacement.
AB - RATIONALE AND OBJECTIVES. A new vascular occlusion device was tested in canine femoral and iliac arteries and in an animal model of a patent ductus arteriosus (PDA). METHODS. Four variations of the vascular plug were placed into 18 iliac or femoral arteries of 17 mongrel dogs. Follow-up angiography was performed 1 hour and, if necessary, 2 hours after placement in all animals, 14 of which were then killed. Three dogs were followed angiographically for 2 weeks to 3 months. The “butterfly” plug was then tested in a canine model of a PDA. RESULTS. All plugs contained thrombi, and 12 of the 18 devices caused complete or nearly complete vascular occlusion within 2 hours. In one dog, one vascular plug had eroded through the vessel wall at 3 months without clinical sequelae. Successful PDA occlusion was achieved in 1 or 2 days in 6 of 8 dogs. Three misplacements occurred, one of which resulted in death. DISCUSSION. The balloon-expandable vascular plug appears to be a promising device for occlusion of blood vessels. Migration has not been observed once the device is placed, thus, sizing of the device appears less critical than with coils. However, modification of the delivery system and considerably more experience with the device are necessary to reduce the risk of misplacement.
KW - Arteries
KW - Therapeutic blockage
KW - Veins
UR - http://www.scopus.com/inward/record.url?scp=0027818116&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0027818116&partnerID=8YFLogxK
U2 - 10.1097/00004424-199312000-00017
DO - 10.1097/00004424-199312000-00017
M3 - Article
C2 - 8307723
AN - SCOPUS:0027818116
SN - 0020-9996
VL - 28
SP - 1165
EP - 1169
JO - Investigative Radiology
JF - Investigative Radiology
IS - 12
ER -