TY - JOUR
T1 - Peri-implantitis induction and resolution around zirconia versus titanium implants
AU - Esplin, Kaleb C.
AU - Tsai, Yi Wen
AU - Vela, Kathryn
AU - Diogenes, Anibal
AU - Hachem, Lea El
AU - Palaiologou, Archontia
AU - Cochran, David L.
AU - Kotsakis, Georgios A.
N1 - Publisher Copyright:
© 2024 The Authors. Journal of Periodontology published by Wiley Periodicals LLC on behalf of American Academy of Periodontology.
PY - 2024
Y1 - 2024
N2 - Background: This study compared titanium and zirconia implant ligature-induced peri-implant defect progression and response to regenerative surgical intervention. Methods: Eight tissue-level endosseous implants were placed in 6 mixed-breed foxhounds, with 2 zirconia and 2 titanium alternating in each hemimandible. Cotton ligatures were placed subgingivally for 16 weeks followed by 8 weeks of spontaneous progression. Standardized radiographs were captured every 2 weeks to evaluate the rate of bone loss. Regenerative surgery was performed utilizing water-jet decontamination, enamel matrix derivative, and locally harvested autogenous bone. After 16 weeks of healing, final radiographic bone levels as well as probing depths, recession, and clinical attachment levels were assessed. Results: All 48 implants integrated successfully. The final average post-ligature radiographic defects were 2.88 and 3.05 mm for titanium and zirconia implants, respectively. There was no significant difference between materials in the rate of radiographic bone loss (p = 0.09). Following regenerative surgery, the total average amount of radiographic bone gain was 1.41 and 1.20 mm for titanium and zirconia, respectively. The percentage of defect fill was 51.56% and 37.98% (p = 0.03) for titanium and zirconia, respectively. Inter-group differences were minimal for clinical parameters at the time of sacrifice including periodontal pocket depths (p = 0.81), recession (p = 0.98), or clinical attachment levels (p = 0.51). Conclusions: No significant difference was found in the rate of peri-implant defect development between titanium and zirconia implants. Both materials gained significant radiographic bone following regenerative surgery with significantly greater defect percentage fill in titanium implants. The final clinical parameters were similar in both groups.
AB - Background: This study compared titanium and zirconia implant ligature-induced peri-implant defect progression and response to regenerative surgical intervention. Methods: Eight tissue-level endosseous implants were placed in 6 mixed-breed foxhounds, with 2 zirconia and 2 titanium alternating in each hemimandible. Cotton ligatures were placed subgingivally for 16 weeks followed by 8 weeks of spontaneous progression. Standardized radiographs were captured every 2 weeks to evaluate the rate of bone loss. Regenerative surgery was performed utilizing water-jet decontamination, enamel matrix derivative, and locally harvested autogenous bone. After 16 weeks of healing, final radiographic bone levels as well as probing depths, recession, and clinical attachment levels were assessed. Results: All 48 implants integrated successfully. The final average post-ligature radiographic defects were 2.88 and 3.05 mm for titanium and zirconia implants, respectively. There was no significant difference between materials in the rate of radiographic bone loss (p = 0.09). Following regenerative surgery, the total average amount of radiographic bone gain was 1.41 and 1.20 mm for titanium and zirconia, respectively. The percentage of defect fill was 51.56% and 37.98% (p = 0.03) for titanium and zirconia, respectively. Inter-group differences were minimal for clinical parameters at the time of sacrifice including periodontal pocket depths (p = 0.81), recession (p = 0.98), or clinical attachment levels (p = 0.51). Conclusions: No significant difference was found in the rate of peri-implant defect development between titanium and zirconia implants. Both materials gained significant radiographic bone following regenerative surgery with significantly greater defect percentage fill in titanium implants. The final clinical parameters were similar in both groups.
KW - animal experimentation
KW - dental implants
KW - peri-implantitis
KW - surface properties
KW - titanium
KW - zirconia
UR - http://www.scopus.com/inward/record.url?scp=85198537102&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85198537102&partnerID=8YFLogxK
U2 - 10.1002/JPER.23-0573
DO - 10.1002/JPER.23-0573
M3 - Article
C2 - 39003566
AN - SCOPUS:85198537102
SN - 0022-3492
JO - Journal of periodontology
JF - Journal of periodontology
ER -