Percutaneous closure of a para-prosthetic aorto-right ventricular fistula

Marvin H. Eng, Joel A. Garcia, Adam Hansgen, Kak Chen Chan, John D. Carroll

Research output: Contribution to journalArticle

10 Scopus citations

Abstract

A 60-year-old woman with increasing dyspnea was found to have a para-prosthetic aorto-right ventricular fistula during post-operative evaluation. Due to her multiple sternotomies, she was considered to be high risk for open surgical repair and referred for percutaneous intervention. A 6/4 mm Amplatzer occluder device (AGA Medical, Golden Valley, MN) was successfully delivered across the fistula with excellent immediate angiographic results.

Original languageEnglish (US)
Pages (from-to)e31-e34
JournalInternational Journal of Cardiology
Volume118
Issue number2
DOIs
StatePublished - May 31 2007

Keywords

  • Amplatzer PDA device
  • Percutaneous intervention
  • Sinus of Valsalva fistula

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Fingerprint Dive into the research topics of 'Percutaneous closure of a para-prosthetic aorto-right ventricular fistula'. Together they form a unique fingerprint.