T2 - Development and Dosimetric Studies of Independent Dose Validation Software on Helical Tomotherapy
AU - he, W.
AU - Shi, C.
AU - Quino, l. Vazquez
AU - Dzintars, E.
AU - Gutiérrez, A.
AU - Stathakis, Sotirios
AU - Alkhatib, H.
AU - Papanikolaou, Nikos
PY - 2010
Y1 - 2010
N2 - Purpose: To develop a 2nd dose validation software for helical TomoTherapy, study the sensitivity of the commission data variation on the final dosimetry impact, and inter‐fraction setup uncertainty effect for patient quality assurance. Method and Materials: A 2nd dose validation software for helical TomoTherapy, called MU‐Tomo, has been developed to independently validates point dose upon archived patient documents, initial coordinates and planned dose of point of calculation, and common dosimetric functions. MU‐Tomo has been validated with a hundred cancer cases (30 prostate, 26 head&neck, 18 lung, 17 pelvis, and 9 brain patients). Sensitivity studies were performed by oscillating fluctuation regions of off‐axis profiles, shifting, and rotating profiles. Daily setup shifts were quantified into systematic and random shifts to evaluate dosimetric variations, separately. Results: For dose validation, 98% of dose differences are within ±5% with mean 0.20%±2.06%. Sensitivity studies show linear response by oscillating OARy, 15 times larger dose variation by shifting OARy than OARx, and less than 1.5% difference by rotating OARx in ±6° and more than 5% in ±1° by rotating OARy. Systematic variations are up to −10.02%±3.00%. Mean random variations are up to −5.65%±1.90%. ANOVA analyses show significant differences among patient random dosimetric variations and systematic dosimetric variations between head&neck‐brain group and body group. Variations are not significantly correlated with treatment fraction number with the Pearson correlation analysis. The overall random dosimetric impacts to each patient are ‐ 0.0053%±1.11%. Conclusion: MU‐Tomo, has been developed for TomoTherapy dose validation. Sensitivity studies on fifty patients have been evaluated that OARy profiles are more sensitive than OARx in dose calculation. Dosimetric consequences due to inter‐fractional setup shifts on a hundred helical tomotherapy patients were assessed. Conflict of Interest: This project was supported in part by Oncology Data Systems, Inc., Oklahoma City, OK, USA.
AB - Purpose: To develop a 2nd dose validation software for helical TomoTherapy, study the sensitivity of the commission data variation on the final dosimetry impact, and inter‐fraction setup uncertainty effect for patient quality assurance. Method and Materials: A 2nd dose validation software for helical TomoTherapy, called MU‐Tomo, has been developed to independently validates point dose upon archived patient documents, initial coordinates and planned dose of point of calculation, and common dosimetric functions. MU‐Tomo has been validated with a hundred cancer cases (30 prostate, 26 head&neck, 18 lung, 17 pelvis, and 9 brain patients). Sensitivity studies were performed by oscillating fluctuation regions of off‐axis profiles, shifting, and rotating profiles. Daily setup shifts were quantified into systematic and random shifts to evaluate dosimetric variations, separately. Results: For dose validation, 98% of dose differences are within ±5% with mean 0.20%±2.06%. Sensitivity studies show linear response by oscillating OARy, 15 times larger dose variation by shifting OARy than OARx, and less than 1.5% difference by rotating OARx in ±6° and more than 5% in ±1° by rotating OARy. Systematic variations are up to −10.02%±3.00%. Mean random variations are up to −5.65%±1.90%. ANOVA analyses show significant differences among patient random dosimetric variations and systematic dosimetric variations between head&neck‐brain group and body group. Variations are not significantly correlated with treatment fraction number with the Pearson correlation analysis. The overall random dosimetric impacts to each patient are ‐ 0.0053%±1.11%. Conclusion: MU‐Tomo, has been developed for TomoTherapy dose validation. Sensitivity studies on fifty patients have been evaluated that OARy profiles are more sensitive than OARx in dose calculation. Dosimetric consequences due to inter‐fractional setup shifts on a hundred helical tomotherapy patients were assessed. Conflict of Interest: This project was supported in part by Oncology Data Systems, Inc., Oklahoma City, OK, USA.
UR - http://www.scopus.com/inward/record.url?scp=85024818280&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85024818280&partnerID=8YFLogxK
U2 - 10.1118/1.3469094
DO - 10.1118/1.3469094
M3 - Article
AN - SCOPUS:85024818280
VL - 37
SP - 3350
JO - Medical Physics
JF - Medical Physics
SN - 0094-2405
IS - 6
ER -