Initial experience with Penumbra Coil 400 versus standard coils in embolization of cerebral aneurysms: A retrospective review

Justin R Mascitelli, Maritsa F. Polykarpou, Aanand A. Patel, Ashwin A. Kamath, Henry Moyle, Aman B. Patel

Research output: Contribution to journalArticle

12 Citations (Scopus)

Abstract

Background and purpose The Penumbra Coil 400 System (PC 400) is the newly introduced platinum coil system designed specifically to enhance filling efficiency by increasing coil diameter. Our goal was to study the packing and treatment advantage of the PC 400's unique geometric configuration compared with conventional coils (controls). Materials and methods 16 aneurysms embolized with the PC 400 in 2011 were compared with 79 equally matched aneurysms embolized with conventional coils from 2004 to 2011. Primary outcomes assessed were acute packing density, embolization time, and the number of coils required for aneurysm occlusion. Results Aneurysm embolization with the PC 400 achieved a higher packing density (36.8% vs 28.1%; p<0.005) and with fewer coils (an average of 3.9 vs 6.1 coils per aneurysm; p<0.05). In addition, the total procedural time for the subjects treated with the PC 400 was significantly less (45.7 vs 64.1 min; p<0.05). There were no procedural complications associated with the PC 400. Conclusions Compared with conventional coils, the PC 400 is more efficient in the embolization of cerebral aneurysms, achieving greater packing density with fewer coils and less time without compromising safety.

Original languageEnglish (US)
Pages (from-to)573-576
Number of pages4
JournalJournal of NeuroInterventional Surgery
Volume5
Issue number6
DOIs
StatePublished - Nov 1 2013
Externally publishedYes

Fingerprint

Intracranial Aneurysm
Aneurysm
Platinum
Safety

ASJC Scopus subject areas

  • Surgery
  • Clinical Neurology

Cite this

Initial experience with Penumbra Coil 400 versus standard coils in embolization of cerebral aneurysms : A retrospective review. / Mascitelli, Justin R; Polykarpou, Maritsa F.; Patel, Aanand A.; Kamath, Ashwin A.; Moyle, Henry; Patel, Aman B.

In: Journal of NeuroInterventional Surgery, Vol. 5, No. 6, 01.11.2013, p. 573-576.

Research output: Contribution to journalArticle

Mascitelli, Justin R ; Polykarpou, Maritsa F. ; Patel, Aanand A. ; Kamath, Ashwin A. ; Moyle, Henry ; Patel, Aman B. / Initial experience with Penumbra Coil 400 versus standard coils in embolization of cerebral aneurysms : A retrospective review. In: Journal of NeuroInterventional Surgery. 2013 ; Vol. 5, No. 6. pp. 573-576.
@article{d41669be485b4da28277f32f19fc59a0,
title = "Initial experience with Penumbra Coil 400 versus standard coils in embolization of cerebral aneurysms: A retrospective review",
abstract = "Background and purpose The Penumbra Coil 400 System (PC 400) is the newly introduced platinum coil system designed specifically to enhance filling efficiency by increasing coil diameter. Our goal was to study the packing and treatment advantage of the PC 400's unique geometric configuration compared with conventional coils (controls). Materials and methods 16 aneurysms embolized with the PC 400 in 2011 were compared with 79 equally matched aneurysms embolized with conventional coils from 2004 to 2011. Primary outcomes assessed were acute packing density, embolization time, and the number of coils required for aneurysm occlusion. Results Aneurysm embolization with the PC 400 achieved a higher packing density (36.8{\%} vs 28.1{\%}; p<0.005) and with fewer coils (an average of 3.9 vs 6.1 coils per aneurysm; p<0.05). In addition, the total procedural time for the subjects treated with the PC 400 was significantly less (45.7 vs 64.1 min; p<0.05). There were no procedural complications associated with the PC 400. Conclusions Compared with conventional coils, the PC 400 is more efficient in the embolization of cerebral aneurysms, achieving greater packing density with fewer coils and less time without compromising safety.",
author = "Mascitelli, {Justin R} and Polykarpou, {Maritsa F.} and Patel, {Aanand A.} and Kamath, {Ashwin A.} and Henry Moyle and Patel, {Aman B.}",
year = "2013",
month = "11",
day = "1",
doi = "10.1136/neurintsurg-2012-010483",
language = "English (US)",
volume = "5",
pages = "573--576",
journal = "Journal of NeuroInterventional Surgery",
issn = "1759-8478",
publisher = "BMJ Publishing Group",
number = "6",

}

TY - JOUR

T1 - Initial experience with Penumbra Coil 400 versus standard coils in embolization of cerebral aneurysms

T2 - A retrospective review

AU - Mascitelli, Justin R

AU - Polykarpou, Maritsa F.

AU - Patel, Aanand A.

AU - Kamath, Ashwin A.

AU - Moyle, Henry

AU - Patel, Aman B.

PY - 2013/11/1

Y1 - 2013/11/1

N2 - Background and purpose The Penumbra Coil 400 System (PC 400) is the newly introduced platinum coil system designed specifically to enhance filling efficiency by increasing coil diameter. Our goal was to study the packing and treatment advantage of the PC 400's unique geometric configuration compared with conventional coils (controls). Materials and methods 16 aneurysms embolized with the PC 400 in 2011 were compared with 79 equally matched aneurysms embolized with conventional coils from 2004 to 2011. Primary outcomes assessed were acute packing density, embolization time, and the number of coils required for aneurysm occlusion. Results Aneurysm embolization with the PC 400 achieved a higher packing density (36.8% vs 28.1%; p<0.005) and with fewer coils (an average of 3.9 vs 6.1 coils per aneurysm; p<0.05). In addition, the total procedural time for the subjects treated with the PC 400 was significantly less (45.7 vs 64.1 min; p<0.05). There were no procedural complications associated with the PC 400. Conclusions Compared with conventional coils, the PC 400 is more efficient in the embolization of cerebral aneurysms, achieving greater packing density with fewer coils and less time without compromising safety.

AB - Background and purpose The Penumbra Coil 400 System (PC 400) is the newly introduced platinum coil system designed specifically to enhance filling efficiency by increasing coil diameter. Our goal was to study the packing and treatment advantage of the PC 400's unique geometric configuration compared with conventional coils (controls). Materials and methods 16 aneurysms embolized with the PC 400 in 2011 were compared with 79 equally matched aneurysms embolized with conventional coils from 2004 to 2011. Primary outcomes assessed were acute packing density, embolization time, and the number of coils required for aneurysm occlusion. Results Aneurysm embolization with the PC 400 achieved a higher packing density (36.8% vs 28.1%; p<0.005) and with fewer coils (an average of 3.9 vs 6.1 coils per aneurysm; p<0.05). In addition, the total procedural time for the subjects treated with the PC 400 was significantly less (45.7 vs 64.1 min; p<0.05). There were no procedural complications associated with the PC 400. Conclusions Compared with conventional coils, the PC 400 is more efficient in the embolization of cerebral aneurysms, achieving greater packing density with fewer coils and less time without compromising safety.

UR - http://www.scopus.com/inward/record.url?scp=84885364860&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84885364860&partnerID=8YFLogxK

U2 - 10.1136/neurintsurg-2012-010483

DO - 10.1136/neurintsurg-2012-010483

M3 - Article

C2 - 22993243

AN - SCOPUS:84885364860

VL - 5

SP - 573

EP - 576

JO - Journal of NeuroInterventional Surgery

JF - Journal of NeuroInterventional Surgery

SN - 1759-8478

IS - 6

ER -