Independent measures of insulin secretion and insulin sensitivity during the same test: The glucagon-insulin tolerance test

M. Dorkhan, D. Tripathy, G. Malm, H. Asgharian, T. Tuomi, L. Groop

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Background. To validate a test for independent assessment of insulin secretion and insulin sensitivity during the same occasion for metabolic studies in clinical practice, i.e. combined glucagon-stimulated C-peptide test and insulin tolerance test (GITT). Subjects and methods. We measured C-peptide response to 0.5 mg of intravenous glucagon followed 30 min later by administration of 0.05 U kg-1 insulin (insulin tolerance test, ITT). Ten subjects with normal glucose tolerance participated on different days in an ITT, glucagon-C-peptide test, ITT followed by glucagon-C-peptide test and glucagon-C-peptide test followed by ITT to establish whether and how the tests could be combined. The test was then repeated in nine patients with type 2 diabetes to investigate its reproducibility. In 20 subjects with varying degrees of glucose tolerance, the test was compared with the Botnia clamp (an intravenous glucose tolerance test combined with a euglycaemic hyperinsulinemic clamp). Results. When ITT preceded the glucagon test, C-peptide response was blunted. Therefore, we first administered glucagon and then insulin (GITT). The KITT from the GITT was reproducible (CV = 13 %) and correlated strongly with the glucose disposal rate from the Botnia clamp (r = 0.87, r 2 = 0.75, P < 0.001). The C-peptide response to glucagon was reproducible (CV = 13 %). The disposition index, providing a measure of beta-cell function adjusted for insulin sensitivity, calculated from the GITT showed good discrimination between individuals with varying degrees of glucose tolerance. Conclusions. The GITT provides simple, reproducible and independent estimates of insulin sensitivity and secretion on the same occasion for metabolic studies in individuals with normal and abnormal glucose tolerance.

Original languageEnglish (US)
Pages (from-to)62-71
Number of pages10
JournalJournal of Internal Medicine
Volume264
Issue number1
DOIs
StatePublished - Jul 2008
Externally publishedYes

Keywords

  • Disposition index
  • Euglycaemic clamp
  • Insulin secretion
  • Insulin sensitivity
  • Insulin tolerance test
  • Type 2 diabetes

ASJC Scopus subject areas

  • Internal Medicine

Fingerprint

Dive into the research topics of 'Independent measures of insulin secretion and insulin sensitivity during the same test: The glucagon-insulin tolerance test'. Together they form a unique fingerprint.

Cite this