TY - JOUR
T1 - Importance of obtaining independent measures of insulin secretion and insulin sensitivity during the same test
T2 - Results with the Botnia clamp
AU - Tripathy, Devjit
AU - Wessman, Ylva
AU - Gullström, Monica
AU - Tuomi, Tiinamaija
AU - Groop, Leif
PY - 2003/5/1
Y1 - 2003/5/1
N2 - OBJECTIVE - To validate and apply a method for independent assessment of insulin secretion and insulin sensitivity (S1) during the same test; that is, an intravenous glucose tolerance test followed by a euglycemic-hyperinsulinemic clamp, also called the Botnia clamp. This test was then applied to nondiabetic subjects with (FH+) and without (FH-) a first-degree family history of diabetes. RESEARCH DESIGN AND METHODS - The Botnia clamp measures the first-phase insulin response (FPIR) to 0.3g/kg glucose i.v. and insulin sensitivity (M-value) from a 2-h euglycemic clamp begun 60 min after the glucose bolus. The M-value obtained during the Botnia clamp was compared with M-values obtained during a regular euglycemic clamp without prior glucose bolus. Repeated tests were performed in random order in subjects with normal and abnormal glucose tolerance. Finally, the test was applied to subjects with and without a family history of type 2 diabetes. RESULTS - S1 and insulin secretion from this test showed a high degree of reproducibility, and the M-value obtained with the Botnia clamp correlated strongly with the M-value from a euglycemic clamp without prior glucose bolus (r = 0.953, P < 0.005). FH+ subjects showed decreased S1 (P = 0.02), but smilar FPIR, compared with FH- subjects. However, insulin secretion adjusted for the degree of insulin resistance was significantly impaired (P = 0.04). CONCLUSIONS - In conclusion, the Botnia clamp provides reliable and independent measures of S1 and β-cell function during the same test. As illustrated above, knowledge of the degree of S1 is mandatory when presenting data on insulin secretion.
AB - OBJECTIVE - To validate and apply a method for independent assessment of insulin secretion and insulin sensitivity (S1) during the same test; that is, an intravenous glucose tolerance test followed by a euglycemic-hyperinsulinemic clamp, also called the Botnia clamp. This test was then applied to nondiabetic subjects with (FH+) and without (FH-) a first-degree family history of diabetes. RESEARCH DESIGN AND METHODS - The Botnia clamp measures the first-phase insulin response (FPIR) to 0.3g/kg glucose i.v. and insulin sensitivity (M-value) from a 2-h euglycemic clamp begun 60 min after the glucose bolus. The M-value obtained during the Botnia clamp was compared with M-values obtained during a regular euglycemic clamp without prior glucose bolus. Repeated tests were performed in random order in subjects with normal and abnormal glucose tolerance. Finally, the test was applied to subjects with and without a family history of type 2 diabetes. RESULTS - S1 and insulin secretion from this test showed a high degree of reproducibility, and the M-value obtained with the Botnia clamp correlated strongly with the M-value from a euglycemic clamp without prior glucose bolus (r = 0.953, P < 0.005). FH+ subjects showed decreased S1 (P = 0.02), but smilar FPIR, compared with FH- subjects. However, insulin secretion adjusted for the degree of insulin resistance was significantly impaired (P = 0.04). CONCLUSIONS - In conclusion, the Botnia clamp provides reliable and independent measures of S1 and β-cell function during the same test. As illustrated above, knowledge of the degree of S1 is mandatory when presenting data on insulin secretion.
UR - http://www.scopus.com/inward/record.url?scp=0042168834&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0042168834&partnerID=8YFLogxK
U2 - 10.2337/diacare.26.5.1395
DO - 10.2337/diacare.26.5.1395
M3 - Article
C2 - 12716795
AN - SCOPUS:0042168834
SN - 0149-5992
VL - 26
SP - 1395
EP - 1401
JO - Diabetes care
JF - Diabetes care
IS - 5
ER -