T1 - Implantable Cardioverter Defibrillator Events in Patients with Asymptomatic Nonsustained Ventricular Tachycardia
T2 - Is Device Implantation Justified?
AU - Russo, Andrea M.
AU - Nayak, Hemal
AU - Verdino, Ralph
AU - Springman, Jamie
AU - Gerstenfeld, Edward
AU - Hsia, Henry
AU - Marchlinski, Francis E.
PY - 2003/12
Y1 - 2003/12
N2 - Primary prevention trials have demonstrated that patients with coronary disease, reduced left ventricular function, and nonsustained ventricular tachycardia (NSVT) have improved survival with implantable cardioverter defibrillator (ICD) therapy, presumably secondary to effective termination of life-threatening arrhythmias. However, stored intracardiac electrograms were not always available and specific arrhythmias leading to ICD therapy were not always known. We examined the occurrence of ICD events in 51 consecutive patients who match the described patient profile to determine the frequency of appropriate and inappropriate ICD therapy. ICD detections were noted in 18 (35%) patients during a median follow-up period of 13.1 months. Appropriate therapy for sustained ventricular tachycardia (VT)/ventricular fibrillation (VF) occurred in 11 (22%) patients, with appropriate shocks in 8 (16%) patients and appropriate antitachycardia pacing (ATP) in 4 (8%) patients. The time to first appropriate therapy occurred at a mean of 17 ± 12 months (median 18 months, range 3-36 months). Inappropriate therapy occurred in 5 (10%) patients with inappropriate shocks in 4 patients and inappropriate ATP in 2 patients. Inappropriate therapy was delivered for supraventricular arrhythmias (SVAs) in 4 patients and for T wave oversensing in 1 patient. The reason for shock therapy was unknown in 1 patient (2%) due to ICD malfunction. The mean arrhythmia rate leading to appropriate therapy for VT/VF was 232 ± 72 beats/min (range 181-400 beats/min), and the mean rate leading to inappropriate therapy for SVT was 168 ± 10 beats/min (range 160-180 beats/min). Patients with coronary disease and asymptomatic NSVT commonly receive appropriate defibrillator therapy. These results support the need for ICD implantation for primary prevention, with attention to careful programming of the detection rate to prevent inappropriate therapy.
AB - Primary prevention trials have demonstrated that patients with coronary disease, reduced left ventricular function, and nonsustained ventricular tachycardia (NSVT) have improved survival with implantable cardioverter defibrillator (ICD) therapy, presumably secondary to effective termination of life-threatening arrhythmias. However, stored intracardiac electrograms were not always available and specific arrhythmias leading to ICD therapy were not always known. We examined the occurrence of ICD events in 51 consecutive patients who match the described patient profile to determine the frequency of appropriate and inappropriate ICD therapy. ICD detections were noted in 18 (35%) patients during a median follow-up period of 13.1 months. Appropriate therapy for sustained ventricular tachycardia (VT)/ventricular fibrillation (VF) occurred in 11 (22%) patients, with appropriate shocks in 8 (16%) patients and appropriate antitachycardia pacing (ATP) in 4 (8%) patients. The time to first appropriate therapy occurred at a mean of 17 ± 12 months (median 18 months, range 3-36 months). Inappropriate therapy occurred in 5 (10%) patients with inappropriate shocks in 4 patients and inappropriate ATP in 2 patients. Inappropriate therapy was delivered for supraventricular arrhythmias (SVAs) in 4 patients and for T wave oversensing in 1 patient. The reason for shock therapy was unknown in 1 patient (2%) due to ICD malfunction. The mean arrhythmia rate leading to appropriate therapy for VT/VF was 232 ± 72 beats/min (range 181-400 beats/min), and the mean rate leading to inappropriate therapy for SVT was 168 ± 10 beats/min (range 160-180 beats/min). Patients with coronary disease and asymptomatic NSVT commonly receive appropriate defibrillator therapy. These results support the need for ICD implantation for primary prevention, with attention to careful programming of the detection rate to prevent inappropriate therapy.
KW - Coronary disease
KW - Implantable defibrillator
KW - Ventricular tachycardia
UR - http://www.scopus.com/inward/record.url?scp=0347992773&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0347992773&partnerID=8YFLogxK
U2 - 10.1111/j.1540-8159.2003.00361.x
DO - 10.1111/j.1540-8159.2003.00361.x
M3 - Article
C2 - 14675014
AN - SCOPUS:0347992773
SN - 0147-8389
VL - 26
SP - 2289
EP - 2295
JO - PACE - Pacing and Clinical Electrophysiology
JF - PACE - Pacing and Clinical Electrophysiology
IS - 12
ER -