TY - JOUR
T1 - Fluoroscopically Guided Percutaneous Jejunostomy with Use of a 21-gauge Needle
T2 - A Prospective Study in 51 Patients
AU - Hu, Hong Tao
AU - Shin, Ji Hoon
AU - Song, Ho Young
AU - Kim, Jin Hyoung
AU - Yoon, Hyun Ki
AU - Gwon, Dong Il
AU - Ko, Gi Young
AU - Sung, Kyu Bo
PY - 2009/12
Y1 - 2009/12
N2 - Purpose: To assess the safety and clinical efficacy of fluoroscopically guided percutaneous jejunostomy with use of a 21-gauge needle and a single anchor technique in 51 patients. Materials and Methods: From November 2006 to January 2009, 51 consecutive patients (42 men and nine women; mean age, 63.7 years) underwent percutaneous jejunostomy under fluoroscopic guidance. A 7.5-F multifunctional coil catheter was used to insufflate the jejunum. The distended jejunum was punctured with a 21-gauge needle, with the inserted coil catheter as the target. A single anchor was used. The technical success, number of punctures, procedure time, complications, and follow-up data including 30-day mortality rate were evaluated. Results: The technical success rate was 100%, and the single anchor technique was used in all but one patient, in whom three anchors were used. The mean number of punctures was 1.7 (range, 1-4), and the mean procedure time was 14.8 minutes (range, 7-29 min). Peritonitis was a major complication in two patients (3.9%), who were treated by changing the catheters from 14 F to 16 F and performing percutaneous drainage procedures. Three minor complications were encountered: superficial cellulitis (n = 2) and severe puncture site pain (n = 1). The 30-day mortality rate was 5.9% (three of 51), although none of the deaths could be attributed to the jejunostomy procedures. Conclusions: Fluoroscopically guided percutaneous jejunostomy with use of a 21-gauge needle and the single anchor technique seems to be safe and effective, with high technical success and low complication rates.
AB - Purpose: To assess the safety and clinical efficacy of fluoroscopically guided percutaneous jejunostomy with use of a 21-gauge needle and a single anchor technique in 51 patients. Materials and Methods: From November 2006 to January 2009, 51 consecutive patients (42 men and nine women; mean age, 63.7 years) underwent percutaneous jejunostomy under fluoroscopic guidance. A 7.5-F multifunctional coil catheter was used to insufflate the jejunum. The distended jejunum was punctured with a 21-gauge needle, with the inserted coil catheter as the target. A single anchor was used. The technical success, number of punctures, procedure time, complications, and follow-up data including 30-day mortality rate were evaluated. Results: The technical success rate was 100%, and the single anchor technique was used in all but one patient, in whom three anchors were used. The mean number of punctures was 1.7 (range, 1-4), and the mean procedure time was 14.8 minutes (range, 7-29 min). Peritonitis was a major complication in two patients (3.9%), who were treated by changing the catheters from 14 F to 16 F and performing percutaneous drainage procedures. Three minor complications were encountered: superficial cellulitis (n = 2) and severe puncture site pain (n = 1). The 30-day mortality rate was 5.9% (three of 51), although none of the deaths could be attributed to the jejunostomy procedures. Conclusions: Fluoroscopically guided percutaneous jejunostomy with use of a 21-gauge needle and the single anchor technique seems to be safe and effective, with high technical success and low complication rates.
UR - http://www.scopus.com/inward/record.url?scp=70450247051&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=70450247051&partnerID=8YFLogxK
U2 - 10.1016/j.jvir.2009.08.012
DO - 10.1016/j.jvir.2009.08.012
M3 - Article
C2 - 19854072
AN - SCOPUS:70450247051
VL - 20
SP - 1583
EP - 1587
JO - Journal of Vascular and Interventional Radiology
JF - Journal of Vascular and Interventional Radiology
SN - 1051-0443
IS - 12
ER -