Evolution of epicardial R wave voltage following experimental coronary artery occlusion: Effects of hyaluronidase

Lair G.T. Ribeiro, L. David Hillis, Peter R. Maroko

Research output: Contribution to journalReview article

Abstract

Summary: The goals of this investigation were: 1) to examine the pattern of evolution of epicardial R wave voltage during the 24 h after experimental coronary artery occlusion; and 2) to determine whether hyaluronidase, an agent shown previously to reduce myocardial ischaemic injury, alters this evolution. Coronary artery occlusion was performed in 36 dogs. In the control dogs, the average R wave voltage (R) recorded over the ischaemic myocardium increased by 7.6 ± 0.8 mV (P <0.001) from before to 15 min after coronary artery occlusion, then gradually returned to baseline over the ensuing 4 h. Subsequently, R wave voltage continued to fall, and 24 h after occlusion, R was 17.8 ± 1.8 mV (P <0.001) less than before occlusion. In the hyaluronidase-treated dogs (500 NF units·kg-1), R recorded over the ischaemic myocardium increased similarly to the controls before hyaluronidase administration. However, in contrast to the control dogs, the administration of hyaluronidase 20 min after occlusion caused R to return to baseline over the ensuing 40 min and 24 h after occlusion, the treated animals lost significantly less R wave voltage than the controls (P <0.001).

Original languageEnglish (US)
Pages (from-to)425-429
Number of pages5
JournalCardiovascular Research
Volume15
Issue number8
DOIs
StatePublished - Jan 1 1981
Externally publishedYes

Fingerprint

Hyaluronoglucosaminidase
Coronary Occlusion
Coronary Vessels
Dogs
Myocardium
Wounds and Injuries

ASJC Scopus subject areas

  • Physiology
  • Cardiology and Cardiovascular Medicine
  • Physiology (medical)

Cite this

Evolution of epicardial R wave voltage following experimental coronary artery occlusion : Effects of hyaluronidase. / Ribeiro, Lair G.T.; Hillis, L. David; Maroko, Peter R.

In: Cardiovascular Research, Vol. 15, No. 8, 01.01.1981, p. 425-429.

Research output: Contribution to journalReview article

Ribeiro, Lair G.T. ; Hillis, L. David ; Maroko, Peter R. / Evolution of epicardial R wave voltage following experimental coronary artery occlusion : Effects of hyaluronidase. In: Cardiovascular Research. 1981 ; Vol. 15, No. 8. pp. 425-429.
@article{d1fd45d7be5d471fa79474f9d2e836a7,
title = "Evolution of epicardial R wave voltage following experimental coronary artery occlusion: Effects of hyaluronidase",
abstract = "Summary: The goals of this investigation were: 1) to examine the pattern of evolution of epicardial R wave voltage during the 24 h after experimental coronary artery occlusion; and 2) to determine whether hyaluronidase, an agent shown previously to reduce myocardial ischaemic injury, alters this evolution. Coronary artery occlusion was performed in 36 dogs. In the control dogs, the average R wave voltage (R) recorded over the ischaemic myocardium increased by 7.6 ± 0.8 mV (P <0.001) from before to 15 min after coronary artery occlusion, then gradually returned to baseline over the ensuing 4 h. Subsequently, R wave voltage continued to fall, and 24 h after occlusion, R was 17.8 ± 1.8 mV (P <0.001) less than before occlusion. In the hyaluronidase-treated dogs (500 NF units·kg-1), R recorded over the ischaemic myocardium increased similarly to the controls before hyaluronidase administration. However, in contrast to the control dogs, the administration of hyaluronidase 20 min after occlusion caused R to return to baseline over the ensuing 40 min and 24 h after occlusion, the treated animals lost significantly less R wave voltage than the controls (P <0.001).",
author = "Ribeiro, {Lair G.T.} and Hillis, {L. David} and Maroko, {Peter R.}",
year = "1981",
month = "1",
day = "1",
doi = "10.1093/cvr/15.8.425",
language = "English (US)",
volume = "15",
pages = "425--429",
journal = "Cardiovascular Research",
issn = "0008-6363",
publisher = "Oxford University Press",
number = "8",

}

TY - JOUR

T1 - Evolution of epicardial R wave voltage following experimental coronary artery occlusion

T2 - Effects of hyaluronidase

AU - Ribeiro, Lair G.T.

AU - Hillis, L. David

AU - Maroko, Peter R.

PY - 1981/1/1

Y1 - 1981/1/1

N2 - Summary: The goals of this investigation were: 1) to examine the pattern of evolution of epicardial R wave voltage during the 24 h after experimental coronary artery occlusion; and 2) to determine whether hyaluronidase, an agent shown previously to reduce myocardial ischaemic injury, alters this evolution. Coronary artery occlusion was performed in 36 dogs. In the control dogs, the average R wave voltage (R) recorded over the ischaemic myocardium increased by 7.6 ± 0.8 mV (P <0.001) from before to 15 min after coronary artery occlusion, then gradually returned to baseline over the ensuing 4 h. Subsequently, R wave voltage continued to fall, and 24 h after occlusion, R was 17.8 ± 1.8 mV (P <0.001) less than before occlusion. In the hyaluronidase-treated dogs (500 NF units·kg-1), R recorded over the ischaemic myocardium increased similarly to the controls before hyaluronidase administration. However, in contrast to the control dogs, the administration of hyaluronidase 20 min after occlusion caused R to return to baseline over the ensuing 40 min and 24 h after occlusion, the treated animals lost significantly less R wave voltage than the controls (P <0.001).

AB - Summary: The goals of this investigation were: 1) to examine the pattern of evolution of epicardial R wave voltage during the 24 h after experimental coronary artery occlusion; and 2) to determine whether hyaluronidase, an agent shown previously to reduce myocardial ischaemic injury, alters this evolution. Coronary artery occlusion was performed in 36 dogs. In the control dogs, the average R wave voltage (R) recorded over the ischaemic myocardium increased by 7.6 ± 0.8 mV (P <0.001) from before to 15 min after coronary artery occlusion, then gradually returned to baseline over the ensuing 4 h. Subsequently, R wave voltage continued to fall, and 24 h after occlusion, R was 17.8 ± 1.8 mV (P <0.001) less than before occlusion. In the hyaluronidase-treated dogs (500 NF units·kg-1), R recorded over the ischaemic myocardium increased similarly to the controls before hyaluronidase administration. However, in contrast to the control dogs, the administration of hyaluronidase 20 min after occlusion caused R to return to baseline over the ensuing 40 min and 24 h after occlusion, the treated animals lost significantly less R wave voltage than the controls (P <0.001).

UR - http://www.scopus.com/inward/record.url?scp=85047680593&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85047680593&partnerID=8YFLogxK

U2 - 10.1093/cvr/15.8.425

DO - 10.1093/cvr/15.8.425

M3 - Review article

VL - 15

SP - 425

EP - 429

JO - Cardiovascular Research

JF - Cardiovascular Research

SN - 0008-6363

IS - 8

ER -