T1 - Estimation of the local statistical noise in positron emission tomography revisited
T2 - Practical implementation
AU - Nickerson, Lisa D.
AU - Narayana, Shalini
AU - Lancaster, Jack L.
AU - Fox, Peter T.
AU - Gao, Jia Hong
N1 - Funding Information:
The authors thank both of the reviewers for very thoughtful and helpful suggestions that greatly improved the quality of the manuscript. Dr. Nickerson is currently supported by NIDA Training Grant DA15036 and has also received support from NIDA Grant R01DA09448 over the course of the preparation of this manuscript.
Copyright:
Copyright 2017 Elsevier B.V., All rights reserved.
PY - 2003/6
Y1 - 2003/6
N2 - The purpose of this report is to implement novel modifications to overcome the limitations of an existing algorithm for estimating the local statistical noise in a positron emission tomography (PET) image without performing repeated measures. The original algorithm is based on a modification of the filtered back-projection algorithm that allows the variance to be estimated using only a single sinogram. In addition, the effects of photon absorption, random coincidences, radioactive decay, and detector nonuniformity are taken into account. However, there are some limitations when applying this method with modern scanners. In particular, it is common practice to interleave the projections in the sinogram (to increase the sampling rate along each projection) and to perform an interpolation when actually back-projecting to reconstruct the images. Both of these procedures introduce covariance among the elements of the projections, which is cumbersome and impractical to deal with using the existing technique for creating a variance image. An alternative image reconstruction scheme that is shown to be equivalent to image reconstruction using traditional filtered back-projection greatly simplifies the estimation of the variance image. The proposed methods were tested by Monte Carlo simulations and by using repeated scans of a uniform phantom filled with F-18. Results demonstrate that the proposed methods are very rigorous and stable when compared to calculations of the local variance using either repeated measures with a large number of measurements, or region-of-interest estimates of the variance, assuming homogeneous variance structure. In addition, strategies for extending the proposed technique are discussed that would permit the estimation of the variance due to measurement error of a pixel in a brain map from both single subjects and pooled group data.
AB - The purpose of this report is to implement novel modifications to overcome the limitations of an existing algorithm for estimating the local statistical noise in a positron emission tomography (PET) image without performing repeated measures. The original algorithm is based on a modification of the filtered back-projection algorithm that allows the variance to be estimated using only a single sinogram. In addition, the effects of photon absorption, random coincidences, radioactive decay, and detector nonuniformity are taken into account. However, there are some limitations when applying this method with modern scanners. In particular, it is common practice to interleave the projections in the sinogram (to increase the sampling rate along each projection) and to perform an interpolation when actually back-projecting to reconstruct the images. Both of these procedures introduce covariance among the elements of the projections, which is cumbersome and impractical to deal with using the existing technique for creating a variance image. An alternative image reconstruction scheme that is shown to be equivalent to image reconstruction using traditional filtered back-projection greatly simplifies the estimation of the variance image. The proposed methods were tested by Monte Carlo simulations and by using repeated scans of a uniform phantom filled with F-18. Results demonstrate that the proposed methods are very rigorous and stable when compared to calculations of the local variance using either repeated measures with a large number of measurements, or region-of-interest estimates of the variance, assuming homogeneous variance structure. In addition, strategies for extending the proposed technique are discussed that would permit the estimation of the variance due to measurement error of a pixel in a brain map from both single subjects and pooled group data.
KW - 3D PET
KW - Image reconstruction
KW - Noise
KW - Positron emission tomography
UR - http://www.scopus.com/inward/record.url?scp=0041737549&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0041737549&partnerID=8YFLogxK
U2 - 10.1016/S1053-8119(03)00104-6
DO - 10.1016/S1053-8119(03)00104-6
M3 - Article
C2 - 12814593
AN - SCOPUS:0041737549
SN - 1053-8119
VL - 19
SP - 442
EP - 456
JO - NeuroImage
JF - NeuroImage
IS - 2
ER -