T1 - Dynamic correction for parallel conductance, GP, and gain factor, α, in invasive murine left ventricular volume measurements
AU - Porterfield, John E.
AU - Kottam, Anil T.G.
AU - Raghavan, Karthik
AU - Escobedo, Daniel
AU - Jenkins, James T.
AU - Larson, Erik R.
AU - Treviño, Rodolfo J.
AU - Valvano, Jonathan W.
AU - Pearce, John A.
AU - Feldman, Marc D.
PY - 2009/12
Y1 - 2009/12
N2 - The conductance catheter technique could be improved by determining instantaneous parallel conductance (GP), which is known to be time varying, and by including a time-varying calibration factor in Baan's equation [α(t)]. We have recently proposed solutions to the problems of both timevarying GP and time-varying α, which we term "admittance" and "Wei's equation," respectively. We validate both our solutions in mice, compared with the currently accepted methods of hypertonic saline (HS) to determine GP and Baan's equation calibrated with both stroke volume (SV) and cuvette. We performed simultaneous echocardiography in closed-chest mice (n = 8) as a reference for left ventricular (LV) volume and demonstrate that an off-center position for the miniaturized pressure-volume (PV) catheter in the LV generates end-systolic and diastolic volumes calculated by admittance with less error (P < 0.03) (-2.49 ± 15.33 μl error) compared with those same parameters calculated by SV calibrated conductance (35.89 ± 73.22 μl error) and by cuvette calibrated conductance (-7.53 ± 16.23 μl ES and -29.10 ± 31.53 μl ED error). To utilize the admittance approach, myocardial permittivity (εm) and conductivity (σm) were calculated in additional mice (n = 7), and those results are used in this calculation. In aortic banded mice (n = 6), increased myocardial permittivity was measured (11,844 ± 2,700 control, 21,267 ± 8,005 banded, P < 0.05), demonstrating that muscle properties vary with disease state. Volume error calculated with respect to echo did not significantly change in aortic banded mice (6.74 ± 13.06 μl, P = not significant). Increased inotropy in response to intravenous dobutamine was detected with greater sensitivity with the admittance technique compared with traditional conductance [4.9 ± 1.4 to 12.5 ± 6.6 mmHg/μl Wei's equation (P < 0.05), 3.3 ± 1.2 to 8.8 ± 5.1 mmHg/μl using Baan's equation (P = not significant)]. New theory and method for instantaneous GP removal, as well as application of Wei's equation, are presented and validated in vivo in mice. We conclude that, for closed-chest mice, admittance (dynamic GP) and Wei's equation (dynamic α) provide more accurate volumes than traditional conductance, are more sensitive to inotropic changes, eliminate the need for hypertonic saline, and can be accurately extended to aortic banded mice.
AB - The conductance catheter technique could be improved by determining instantaneous parallel conductance (GP), which is known to be time varying, and by including a time-varying calibration factor in Baan's equation [α(t)]. We have recently proposed solutions to the problems of both timevarying GP and time-varying α, which we term "admittance" and "Wei's equation," respectively. We validate both our solutions in mice, compared with the currently accepted methods of hypertonic saline (HS) to determine GP and Baan's equation calibrated with both stroke volume (SV) and cuvette. We performed simultaneous echocardiography in closed-chest mice (n = 8) as a reference for left ventricular (LV) volume and demonstrate that an off-center position for the miniaturized pressure-volume (PV) catheter in the LV generates end-systolic and diastolic volumes calculated by admittance with less error (P < 0.03) (-2.49 ± 15.33 μl error) compared with those same parameters calculated by SV calibrated conductance (35.89 ± 73.22 μl error) and by cuvette calibrated conductance (-7.53 ± 16.23 μl ES and -29.10 ± 31.53 μl ED error). To utilize the admittance approach, myocardial permittivity (εm) and conductivity (σm) were calculated in additional mice (n = 7), and those results are used in this calculation. In aortic banded mice (n = 6), increased myocardial permittivity was measured (11,844 ± 2,700 control, 21,267 ± 8,005 banded, P < 0.05), demonstrating that muscle properties vary with disease state. Volume error calculated with respect to echo did not significantly change in aortic banded mice (6.74 ± 13.06 μl, P = not significant). Increased inotropy in response to intravenous dobutamine was detected with greater sensitivity with the admittance technique compared with traditional conductance [4.9 ± 1.4 to 12.5 ± 6.6 mmHg/μl Wei's equation (P < 0.05), 3.3 ± 1.2 to 8.8 ± 5.1 mmHg/μl using Baan's equation (P = not significant)]. New theory and method for instantaneous GP removal, as well as application of Wei's equation, are presented and validated in vivo in mice. We conclude that, for closed-chest mice, admittance (dynamic GP) and Wei's equation (dynamic α) provide more accurate volumes than traditional conductance, are more sensitive to inotropic changes, eliminate the need for hypertonic saline, and can be accurately extended to aortic banded mice.
KW - Admittance
KW - Conductance catheter
KW - Left ventricular
KW - Mouse
KW - Parallel conductance
KW - Pressure volume relationship
KW - α
UR - http://www.scopus.com/inward/record.url?scp=73449147682&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=73449147682&partnerID=8YFLogxK
U2 - 10.1152/japplphysiol.91322.2008
DO - 10.1152/japplphysiol.91322.2008
M3 - Article
C2 - 19696357
AN - SCOPUS:73449147682
VL - 107
SP - 1693
EP - 1703
JO - Journal of Applied Physiology
JF - Journal of Applied Physiology
SN - 0161-7567
IS - 6
ER -