TY - JOUR
T1 - Diagnostic utility of smartwatch technology for atrial fibrillation detection - a systematic analysis
AU - Elbey, Mehmet Ali
AU - Young, Daisy
AU - Kanuri, Sri Harsha
AU - Akella, Krishna
AU - Murtaza, Ghulam
AU - Garg, Jalaj
AU - Atkins, Donita
AU - Bommana, Sudha
AU - Sharma, Sharan
AU - Turagam, Mohit
AU - Pillarisetti, Jayashree
AU - Park, Peter
AU - Tummala, Rangarao
AU - Shah, Alap
AU - Koerber, Scott
AU - Shivamurthy, Poojita
AU - Vasamreddy, Chandrasekhar
AU - Gopinathannair, Rakesh
AU - Lakkireddy, Dhanunjaya
N1 - Publisher Copyright:
© 2021 CardioFront LLC. All rights reserved.
PY - 2021/4
Y1 - 2021/4
N2 - Background: Smartphone technologies have been recently developed to assess heart rate and rhythm, but their role in accurately detecting atrial fibrillation (AF) remains unknown. Objective: We sought to perform a meta-analysis using prospective studies comparing Smartwatch technology with current monitoring standards for AF detection (ECG, Holter, Patch Monitor, ILR). Methods: We performed a comprehensive literature search for prospective studies comparing Smartwatch technology simultaneously with current monitoring standards (ECG, Holter, and Patch monitor) for AF detection since inception to November 25th, 2019. The outcome studied was the accuracy of AF detection. Accuracy was determined with concomitant usage of ECG monitoring, Holter monitoring, loop recorder, or patch monitoring. Results: A total of 9 observational studies were included comparing smartwatch technology, 3 using single-lead ECG monitoring, and six studies using photoplethysmography with routine AF monitoring strategies. A total of 1559 patients were enrolled (mean age 63.5 years, 39.5% had an AF history). The mean monitoring time was 75.6 days. Smartwatch was non-inferior to composite ECG monitoring strategies (OR 1.06, 95% CI 0.93 - 1.21, p=0.37), composite 12 lead ECG/Holter monitoring (OR 0.90, 95% CI 0.62 - 1.30, p=0.57) and patch monitoring (OR 1.28, 95% CI 0.84 - 1.94, p=0.24) for AF detection. The sensitivity and specificity for AF detection using a smartwatch was 95% and 94%, respectively. Conclusions: Smartwatch based single-lead ECG and photoplethysmography appear to be reasonable alternatives for AF monitoring.
AB - Background: Smartphone technologies have been recently developed to assess heart rate and rhythm, but their role in accurately detecting atrial fibrillation (AF) remains unknown. Objective: We sought to perform a meta-analysis using prospective studies comparing Smartwatch technology with current monitoring standards for AF detection (ECG, Holter, Patch Monitor, ILR). Methods: We performed a comprehensive literature search for prospective studies comparing Smartwatch technology simultaneously with current monitoring standards (ECG, Holter, and Patch monitor) for AF detection since inception to November 25th, 2019. The outcome studied was the accuracy of AF detection. Accuracy was determined with concomitant usage of ECG monitoring, Holter monitoring, loop recorder, or patch monitoring. Results: A total of 9 observational studies were included comparing smartwatch technology, 3 using single-lead ECG monitoring, and six studies using photoplethysmography with routine AF monitoring strategies. A total of 1559 patients were enrolled (mean age 63.5 years, 39.5% had an AF history). The mean monitoring time was 75.6 days. Smartwatch was non-inferior to composite ECG monitoring strategies (OR 1.06, 95% CI 0.93 - 1.21, p=0.37), composite 12 lead ECG/Holter monitoring (OR 0.90, 95% CI 0.62 - 1.30, p=0.57) and patch monitoring (OR 1.28, 95% CI 0.84 - 1.94, p=0.24) for AF detection. The sensitivity and specificity for AF detection using a smartwatch was 95% and 94%, respectively. Conclusions: Smartwatch based single-lead ECG and photoplethysmography appear to be reasonable alternatives for AF monitoring.
KW - Atrial Fibrillation
KW - Photoplethysmography
KW - Smartwatch
UR - http://www.scopus.com/inward/record.url?scp=85119704061&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85119704061&partnerID=8YFLogxK
M3 - Article
AN - SCOPUS:85119704061
SN - 1941-6911
VL - 13
JO - Journal of Atrial Fibrillation
JF - Journal of Atrial Fibrillation
IS - 6
ER -