Comparison of topical hemostatic agents in a swine model of extremity arterial hemorrhage: BloodSTOP iX Battle Matrix vs. Quikclot Combat Gauze

Huixi Li, Lin Wang, Amjad Alwaal, Yung Chin Lee, Amanda Reed-Maldonado, Taylor A. Spangler, Lia Banie, Reginald B. O’Hara, Guiting Lin

Research output: Contribution to journalArticlepeer-review

22 Scopus citations

Abstract

BloodSTOP iX Battle Matrix (BM) and QuikClot Combat Gauze (CG) have both been used to treat traumatic bleeding. The purpose of this study was to examine the efficacy and initial safety of both products in a swine extremity arterial hemorrhage model, which mimics combat injury. Swine (37.13 ± 0.56 kg, NBM = 11, NCG = 9) were anesthetized and splenectomized. We then isolated the femoral arteries and performed a 6 mm arteriotomy. After 45 s of free bleeding, either BM or CG was applied. Fluid resuscitation was provided to maintain a mean arterial pressure of 65 mmHg. Animals were observed for three hours or until death. Fluoroscopic angiography and wound stability challenge tests were performed on survivors. Tissue samples were collected for histologic examination. Stable hemostasis was achieved in 11/11 BM and 5/9 CG subjects, with recovery of mean arterial pressure and animal survival for three hours (p < 0.05, Odds Ratio (OR) = 18.82 (0.85–415.3)). Time to stable hemostasis was shorter for the BM-treated group (4.8 ± 2.5 min vs. 58 ± 20.1 min; Median = 2, Interquartile Range (IQR) = 0 min vs. Median = 60, IQR = 120 min; p < 0.05) and experienced longer total stable hemostasis (175.2 ± 2.5 min vs. 92.4 ± 29.9 min; Median = 178, IQR = 0 min vs. Median = 120, IQR = 178 min; p < 0.05). Post-treatment blood loss was lower with BM (9.5 ± 2.4 mL/kg, Median = 10.52, IQR = 13.63 mL/kg) compared to CG (29.9 ± 9.9 mL/kg, Median = 29.38, IQR = 62.44 mL/kg) (p = 0.2875). Standard BM products weighed less compared to CG (6.9 ± 0.03 g vs. 20.2 ± 0.4 g) (p < 0.05) and absorbed less blood (3.4 ± 0.8 g vs. 41.9 ± 12.3 g) (p < 0.05). Fluoroscopic angiography showed recanalization in 5/11 (BM) and 0/5 (CG) surviving animals (p = 0.07, OR = 9.3 (0.41–208.8)). The wound stability challenge test resulted in wound re-bleeding in 1/11 (BM) and 5/5 (CG) surviving animals (p < 0.05, OR = 0.013 (0.00045–0.375)). Histologic evidence indicated no wound site, distal limb or major organ damage in either group. BM is more effective and portable in treating arterial hemorrhage compared to CG. There was no histologic evidence of further damage in either group.

Original languageEnglish (US)
Article number545
JournalInternational journal of molecular sciences
Volume17
Issue number4
DOIs
StatePublished - Apr 12 2016
Externally publishedYes

Keywords

  • BloodSTOP Battle Matrix
  • Hemorrhage control
  • Hemostatic agents
  • QuikClot Combat Gauze
  • Swine

ASJC Scopus subject areas

  • Catalysis
  • Molecular Biology
  • Spectroscopy
  • Computer Science Applications
  • Physical and Theoretical Chemistry
  • Organic Chemistry
  • Inorganic Chemistry

Fingerprint

Dive into the research topics of 'Comparison of topical hemostatic agents in a swine model of extremity arterial hemorrhage: BloodSTOP iX Battle Matrix vs. Quikclot Combat Gauze'. Together they form a unique fingerprint.

Cite this