TY - JOUR
T1 - Comparison of PD BLADE with fat saturation (FS), PD FS and T2 3D DESS with water excitation (WE) in detecting articular knee cartilage defects
AU - Lavdas, Eleftherios
AU - Topalzikis, Theofilos
AU - Mavroidis, Panayiotis
AU - Kyriakis, Ioannis
AU - Roka, Violeta
AU - Kostopoulos, Spiros
AU - Glotsos, Dimitrios
AU - Zilidis, Christos
AU - Stathakis, Sotiris
AU - Tsagkalis, Antonios
AU - Papanikolaou, Nikos
AU - Batsikas, Georgios
AU - Arvanitis, Dimitrios L.
AU - Vassiou, Katerina
PY - 2013/10
Y1 - 2013/10
N2 - The purpose of this study, is to compare the sequences: 1) proton density (PD) BLADE (BLADE is a PROPELLER-equivalent implementation of the Siemens Medical System) with fat saturation (FS) coronal (COR), 2) PD FS COR, 3) multi-planar reconstruction (MPR) with 3. mm slice thickness and 4) multi-planar reconstruction (MPR) with 1.5. mm slice thickness, both from the T2 3D-double-echo steady state (DESS) with water excitation (WE) sagittal (SAG), regarding their abilities to identify changes in the femorotibial condyle cartilage in knee MRI examinations. Thirty three consecutive patients with osteoarthritis (18 females, 15 males; mean age 56. years, range 37-71. years), who had been routinely scanned for knee examination using the previously mentioned image acquisition techniques, participated in the study. A quantitative analysis was performed based on the relative contrast (ReCON) measurements, which were taken both on normal tissues as well as on pathologies. Additionally, a qualitative analysis was performed by two radiologists. Motion and pulsatile flow artifacts were evaluated. The PD BLADE FS COR sequence produced images of higher contrast between Menisci and Cartilage, Fluid and Cartilage, Pathologies and Cartilage as well as of the Conspicuousness Superficial Cartilage and it was found to be superior to the other sequences (p. <. 0.001). The sequences T2 3D DESS 1.5. mm and T2 3D DESS 3. mm were significantly superior to the PD BLADE FS COR and the PD FS COR sequences in the visualization of Bone and Cartilage and the Conspicuousness Deep Surface Cartilage. This pattern of results is also confirmed by the quantitative analysis. PD FS BLADE sequences are ideal for the depiction of the cartilage pathologies compared to the conventional PD FS and T2 3D DESS sequences.
AB - The purpose of this study, is to compare the sequences: 1) proton density (PD) BLADE (BLADE is a PROPELLER-equivalent implementation of the Siemens Medical System) with fat saturation (FS) coronal (COR), 2) PD FS COR, 3) multi-planar reconstruction (MPR) with 3. mm slice thickness and 4) multi-planar reconstruction (MPR) with 1.5. mm slice thickness, both from the T2 3D-double-echo steady state (DESS) with water excitation (WE) sagittal (SAG), regarding their abilities to identify changes in the femorotibial condyle cartilage in knee MRI examinations. Thirty three consecutive patients with osteoarthritis (18 females, 15 males; mean age 56. years, range 37-71. years), who had been routinely scanned for knee examination using the previously mentioned image acquisition techniques, participated in the study. A quantitative analysis was performed based on the relative contrast (ReCON) measurements, which were taken both on normal tissues as well as on pathologies. Additionally, a qualitative analysis was performed by two radiologists. Motion and pulsatile flow artifacts were evaluated. The PD BLADE FS COR sequence produced images of higher contrast between Menisci and Cartilage, Fluid and Cartilage, Pathologies and Cartilage as well as of the Conspicuousness Superficial Cartilage and it was found to be superior to the other sequences (p. <. 0.001). The sequences T2 3D DESS 1.5. mm and T2 3D DESS 3. mm were significantly superior to the PD BLADE FS COR and the PD FS COR sequences in the visualization of Bone and Cartilage and the Conspicuousness Deep Surface Cartilage. This pattern of results is also confirmed by the quantitative analysis. PD FS BLADE sequences are ideal for the depiction of the cartilage pathologies compared to the conventional PD FS and T2 3D DESS sequences.
KW - 1.5T MRI
KW - BLADE proton density with fat saturation sequences
KW - Cartilage defects
KW - Knee MRI
KW - T2 3D DESS
UR - http://www.scopus.com/inward/record.url?scp=84883742218&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84883742218&partnerID=8YFLogxK
U2 - 10.1016/j.mri.2013.06.007
DO - 10.1016/j.mri.2013.06.007
M3 - Article
C2 - 23876261
AN - SCOPUS:84883742218
SN - 0730-725X
VL - 31
SP - 1255
EP - 1262
JO - Magnetic Resonance Imaging
JF - Magnetic Resonance Imaging
IS - 8