N2 - The Use of Endosseous Dental Implants as transmucosal devices necessitates the successful integration of three different tissues: bone, connective tissue, and epithelium. So far, studies have predominantly focused on hard tissue integration. Much less is known about soft tissues. This study examined the dimensions of the implantogingival junction in relation to clinically healthy unloaded and loaded nonsubmerged implants. In total, 69 titanium plasma-sprayed (TPS) and sandblasted acid-etched (SLA) implants were placed in an alternating fashion in six foxhounds and allowed to heal for 3 months. Two dogs were sacrificed after the initial healing period. The remaining four dogs had crowns fabricated that were allowed to function for up to 12 months. These animals were sacrificed after 3 and 12 months of loading. Histometric analysis of undecalcified histologic sections included the evaluation of the sulcus depth (SD), the dimensions of the junctional epithelium (JE), and the connective tissue contact (CTC). Mean values in the 3 month unloaded group were 0.49 mm for SD, 1.16 mm for JE, and 1.36 mm for CTC. These dimensions were 0.50 mm for SD, 1.44 mm for JE, and 1.01 mm for CTC for the 3 month loaded group. After 12 months of loading, these values were 0.16 mm for SD, 1.88 mm for JE, and 1.05 mm for CTC. The sum of these measurements was similar for the different time points and similar to the same dimensions around teeth. TPS and SLA surfaces had no influence on the evaluated parameters (P > 0.05). The data suggest that a biologic width exists around unloaded and loaded nonsubmerged one-part titanium implants and that this is a physiologically formed and stable dimension as is found around teeth.
AB - The Use of Endosseous Dental Implants as transmucosal devices necessitates the successful integration of three different tissues: bone, connective tissue, and epithelium. So far, studies have predominantly focused on hard tissue integration. Much less is known about soft tissues. This study examined the dimensions of the implantogingival junction in relation to clinically healthy unloaded and loaded nonsubmerged implants. In total, 69 titanium plasma-sprayed (TPS) and sandblasted acid-etched (SLA) implants were placed in an alternating fashion in six foxhounds and allowed to heal for 3 months. Two dogs were sacrificed after the initial healing period. The remaining four dogs had crowns fabricated that were allowed to function for up to 12 months. These animals were sacrificed after 3 and 12 months of loading. Histometric analysis of undecalcified histologic sections included the evaluation of the sulcus depth (SD), the dimensions of the junctional epithelium (JE), and the connective tissue contact (CTC). Mean values in the 3 month unloaded group were 0.49 mm for SD, 1.16 mm for JE, and 1.36 mm for CTC. These dimensions were 0.50 mm for SD, 1.44 mm for JE, and 1.01 mm for CTC for the 3 month loaded group. After 12 months of loading, these values were 0.16 mm for SD, 1.88 mm for JE, and 1.05 mm for CTC. The sum of these measurements was similar for the different time points and similar to the same dimensions around teeth. TPS and SLA surfaces had no influence on the evaluated parameters (P > 0.05). The data suggest that a biologic width exists around unloaded and loaded nonsubmerged one-part titanium implants and that this is a physiologically formed and stable dimension as is found around teeth.
KW - Animal studies
KW - Biologic width
KW - Dental implants/endosseous
KW - Soft tissue
KW - Titanium
UR - http://www.scopus.com/inward/record.url?scp=0031067775&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0031067775&partnerID=8YFLogxK
U2 - 10.1902/jop.1997.68.2.186
DO - 10.1902/jop.1997.68.2.186
M3 - Article
C2 - 9058338
AN - SCOPUS:0031067775
SN - 0022-3492
VL - 68
SP - 186
EP - 198
JO - Journal of periodontology
JF - Journal of periodontology
IS - 2
ER -