A rapid, automated method for the performance of the Limulus amoebocyte lysate endotoxin assay has been developed by using the Abbott MS-2 Microbiology System. This instrument automatically determines sequential changes in the optical density of up to 176 samples at 1- or 5-min increments during a 1-h assay period. Graphic representation of optical density changes can be viewed on a cathode-ray tube or reproduced by using a hard-copy printer. Limulus amoebocyte lysate preparations that were obtained from different commercial producers and that had similar endotoxin sensitivities by the conventional gelation method varied somewhat in reactivity when determinations were based upon rate changes in optical density. Lysates from Associates of Cape Cod, Difco Laboratories, and M.A. Bioproducts were the most readily adaptable to the MS-2 System. Use of the MS-2 system increased the sensitivity of these preparations from 60- to 250-fold, and as little as 1 pg/ml was detected. Adaptation of the MS-2 instrument for this purpose provides an objective, reproducible, automated method for the performance of Limulus amoebocyte lysate tests on a variety of fluids.

Original languageEnglish (US)
Pages (from-to)1316-1320
Number of pages5
JournalApplied and Environmental Microbiology
Volume41
Issue number6
StatePublished - 1981

Fingerprint

Limulus
Horseshoe Crabs
Automation
microbiology
automation
Microbiology
absorbance
endotoxins
Endotoxins
Cathode Ray Tube
printers
assay
biobased products
Gadiformes
testing
assays
gelation
methodology
fold
fluid

ASJC Scopus subject areas

  • Biotechnology
  • Environmental Science(all)
  • Microbiology

Cite this

Automation of the Limulus amoebocyte lysate test by using the Abbott MS-2 microbiology system. / Jorgensen, J. H.; Alexander, G. A.

In: Applied and Environmental Microbiology, Vol. 41, No. 6, 1981, p. 1316-1320.

Research output: Contribution to journalArticle

@article{3b9b20e0e42f494cb53d550eea14e2b3,
title = "Automation of the Limulus amoebocyte lysate test by using the Abbott MS-2 microbiology system",
abstract = "A rapid, automated method for the performance of the Limulus amoebocyte lysate endotoxin assay has been developed by using the Abbott MS-2 Microbiology System. This instrument automatically determines sequential changes in the optical density of up to 176 samples at 1- or 5-min increments during a 1-h assay period. Graphic representation of optical density changes can be viewed on a cathode-ray tube or reproduced by using a hard-copy printer. Limulus amoebocyte lysate preparations that were obtained from different commercial producers and that had similar endotoxin sensitivities by the conventional gelation method varied somewhat in reactivity when determinations were based upon rate changes in optical density. Lysates from Associates of Cape Cod, Difco Laboratories, and M.A. Bioproducts were the most readily adaptable to the MS-2 System. Use of the MS-2 system increased the sensitivity of these preparations from 60- to 250-fold, and as little as 1 pg/ml was detected. Adaptation of the MS-2 instrument for this purpose provides an objective, reproducible, automated method for the performance of Limulus amoebocyte lysate tests on a variety of fluids.",
author = "Jorgensen, {J. H.} and Alexander, {G. A.}",
year = "1981",
language = "English (US)",
volume = "41",
pages = "1316--1320",
journal = "Applied and Environmental Microbiology",
issn = "0099-2240",
publisher = "American Society for Microbiology",
number = "6",

}

TY - JOUR

T1 - Automation of the Limulus amoebocyte lysate test by using the Abbott MS-2 microbiology system

AU - Jorgensen, J. H.

AU - Alexander, G. A.

PY - 1981

Y1 - 1981

N2 - A rapid, automated method for the performance of the Limulus amoebocyte lysate endotoxin assay has been developed by using the Abbott MS-2 Microbiology System. This instrument automatically determines sequential changes in the optical density of up to 176 samples at 1- or 5-min increments during a 1-h assay period. Graphic representation of optical density changes can be viewed on a cathode-ray tube or reproduced by using a hard-copy printer. Limulus amoebocyte lysate preparations that were obtained from different commercial producers and that had similar endotoxin sensitivities by the conventional gelation method varied somewhat in reactivity when determinations were based upon rate changes in optical density. Lysates from Associates of Cape Cod, Difco Laboratories, and M.A. Bioproducts were the most readily adaptable to the MS-2 System. Use of the MS-2 system increased the sensitivity of these preparations from 60- to 250-fold, and as little as 1 pg/ml was detected. Adaptation of the MS-2 instrument for this purpose provides an objective, reproducible, automated method for the performance of Limulus amoebocyte lysate tests on a variety of fluids.

AB - A rapid, automated method for the performance of the Limulus amoebocyte lysate endotoxin assay has been developed by using the Abbott MS-2 Microbiology System. This instrument automatically determines sequential changes in the optical density of up to 176 samples at 1- or 5-min increments during a 1-h assay period. Graphic representation of optical density changes can be viewed on a cathode-ray tube or reproduced by using a hard-copy printer. Limulus amoebocyte lysate preparations that were obtained from different commercial producers and that had similar endotoxin sensitivities by the conventional gelation method varied somewhat in reactivity when determinations were based upon rate changes in optical density. Lysates from Associates of Cape Cod, Difco Laboratories, and M.A. Bioproducts were the most readily adaptable to the MS-2 System. Use of the MS-2 system increased the sensitivity of these preparations from 60- to 250-fold, and as little as 1 pg/ml was detected. Adaptation of the MS-2 instrument for this purpose provides an objective, reproducible, automated method for the performance of Limulus amoebocyte lysate tests on a variety of fluids.

UR - http://www.scopus.com/inward/record.url?scp=0019830474&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0019830474&partnerID=8YFLogxK

M3 - Article

C2 - 7247396

AN - SCOPUS:0019830474

VL - 41

SP - 1316

EP - 1320

JO - Applied and Environmental Microbiology

JF - Applied and Environmental Microbiology

SN - 0099-2240

IS - 6

ER -