A Monte Carlo model for independent dose verification in serial tomotherapy

Vikren Sarkar, Sotirios Stathakis, Nikos Papanikolaou

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Due to the very high complexity of IMRT treatment plans, it is imperative to perform dose verification, preferably before patient delivery. The aim of this project is to develop a Monte-Carlo-based model to verify the final dose distributions of plans developed using the Peacock system (CORVUS Treatment Planning System and MIMiC collimator). The system delivers radiation through arc therapy and uses sinogram files to determine the state of each of the multileaf collimator leaves. In-house software was developed using Matlab to decode the sinograms and create blocklets that are used as input in an MCSIM model of the MIMiC collimator attached to a Varian Clinac 600C. After validating the model, a prostate and head and neck case were simulated. The CORVUS-predicted dose distributions were compared with the Monte Carlo dose distributions. As expected, the results agreed very closely for the homogeneous case of the prostate but there were large discrepancies observed for the more heterogeneous head and neck case.

Original languageEnglish (US)
Pages (from-to)385-391
Number of pages7
JournalTechnology in Cancer Research and Treatment
Volume7
Issue number5
StatePublished - Oct 2008

Fingerprint

Prostate
Neck
Head
Therapeutics
Software
Radiation

Keywords

  • Dose verification
  • IMRT
  • Monte Carlo
  • Serial tomotherapy

ASJC Scopus subject areas

  • Cancer Research
  • Oncology

Cite this

A Monte Carlo model for independent dose verification in serial tomotherapy. / Sarkar, Vikren; Stathakis, Sotirios; Papanikolaou, Nikos.

In: Technology in Cancer Research and Treatment, Vol. 7, No. 5, 10.2008, p. 385-391.

Research output: Contribution to journalArticle

@article{c10896554b734774b5e89731b00ac55d,
title = "A Monte Carlo model for independent dose verification in serial tomotherapy",
abstract = "Due to the very high complexity of IMRT treatment plans, it is imperative to perform dose verification, preferably before patient delivery. The aim of this project is to develop a Monte-Carlo-based model to verify the final dose distributions of plans developed using the Peacock system (CORVUS Treatment Planning System and MIMiC collimator). The system delivers radiation through arc therapy and uses sinogram files to determine the state of each of the multileaf collimator leaves. In-house software was developed using Matlab to decode the sinograms and create blocklets that are used as input in an MCSIM model of the MIMiC collimator attached to a Varian Clinac 600C. After validating the model, a prostate and head and neck case were simulated. The CORVUS-predicted dose distributions were compared with the Monte Carlo dose distributions. As expected, the results agreed very closely for the homogeneous case of the prostate but there were large discrepancies observed for the more heterogeneous head and neck case.",
keywords = "Dose verification, IMRT, Monte Carlo, Serial tomotherapy",
author = "Vikren Sarkar and Sotirios Stathakis and Nikos Papanikolaou",
year = "2008",
month = "10",
language = "English (US)",
volume = "7",
pages = "385--391",
journal = "Technology in Cancer Research and Treatment",
issn = "1533-0346",
publisher = "Adenine Press",
number = "5",

}

TY - JOUR

T1 - A Monte Carlo model for independent dose verification in serial tomotherapy

AU - Sarkar, Vikren

AU - Stathakis, Sotirios

AU - Papanikolaou, Nikos

PY - 2008/10

Y1 - 2008/10

N2 - Due to the very high complexity of IMRT treatment plans, it is imperative to perform dose verification, preferably before patient delivery. The aim of this project is to develop a Monte-Carlo-based model to verify the final dose distributions of plans developed using the Peacock system (CORVUS Treatment Planning System and MIMiC collimator). The system delivers radiation through arc therapy and uses sinogram files to determine the state of each of the multileaf collimator leaves. In-house software was developed using Matlab to decode the sinograms and create blocklets that are used as input in an MCSIM model of the MIMiC collimator attached to a Varian Clinac 600C. After validating the model, a prostate and head and neck case were simulated. The CORVUS-predicted dose distributions were compared with the Monte Carlo dose distributions. As expected, the results agreed very closely for the homogeneous case of the prostate but there were large discrepancies observed for the more heterogeneous head and neck case.

AB - Due to the very high complexity of IMRT treatment plans, it is imperative to perform dose verification, preferably before patient delivery. The aim of this project is to develop a Monte-Carlo-based model to verify the final dose distributions of plans developed using the Peacock system (CORVUS Treatment Planning System and MIMiC collimator). The system delivers radiation through arc therapy and uses sinogram files to determine the state of each of the multileaf collimator leaves. In-house software was developed using Matlab to decode the sinograms and create blocklets that are used as input in an MCSIM model of the MIMiC collimator attached to a Varian Clinac 600C. After validating the model, a prostate and head and neck case were simulated. The CORVUS-predicted dose distributions were compared with the Monte Carlo dose distributions. As expected, the results agreed very closely for the homogeneous case of the prostate but there were large discrepancies observed for the more heterogeneous head and neck case.

KW - Dose verification

KW - IMRT

KW - Monte Carlo

KW - Serial tomotherapy

UR - http://www.scopus.com/inward/record.url?scp=53549125817&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=53549125817&partnerID=8YFLogxK

M3 - Article

VL - 7

SP - 385

EP - 391

JO - Technology in Cancer Research and Treatment

JF - Technology in Cancer Research and Treatment

SN - 1533-0346

IS - 5

ER -