TY - JOUR
T1 - A controlled study of transesophageal echocardiography to guide central venous catheter placement in congenital heart surgery patients
AU - Andropoulos, Dean B.
AU - Stayer, Stephen A.
AU - Bent, Sabrina T.
AU - Campos, Carlos J.
AU - Bezold, Louis I.
AU - Alvarez, Melquiades
AU - Fraser, Charles D.
PY - 1999
Y1 - 1999
N2 - Transesophageal echocardiography (TEE) and central venous catheter (CVC) placement are often used during congenital cardiac surgery. Complications of CVC placement include cardiac perforation, inadvertent arterial placement, and erroneous hemodynamic data from unrecognized malposition. In this study, we used a prospective, randomized, controlled design to evaluate the use of TEE to guide depth of insertion and confirm superior vena cava cannulation, and to improve the percentage of correctly placed CVCs and reduce complications of CVC placement. One hundred forty-five patients were studied. Eighty patients were randomized to have subclavian vein insertion, 64 to have internal jugular insertion, and 1 to have external jugular insertion of CVC. TEE-guided CVC placement resulted in 100% correct placement when assessed by preoperative TEE, versus 86% in the control group (72 of 72 vs 63 of 73; P = 0.01). There was no difference in correct placement between the two groups when assessed by postoperative chest radiograph (81.9% TEE versus 75.3% control; P = not significant). One significant complication, a superior vena cava perforation, occurred in the control group. Time to placement was 9.6 min in the TEE group versus 8.0 min in the control group (P = 0.015). Implications: Transesophageal echocardiography can be used to guide central venous catheter placement in congenital heart surgery. Central venous catheters that seem to be located high in the right atrium by chest radiograph in these patients are often actually in the superior vena cava and pose little risk of cardiac perforation.
AB - Transesophageal echocardiography (TEE) and central venous catheter (CVC) placement are often used during congenital cardiac surgery. Complications of CVC placement include cardiac perforation, inadvertent arterial placement, and erroneous hemodynamic data from unrecognized malposition. In this study, we used a prospective, randomized, controlled design to evaluate the use of TEE to guide depth of insertion and confirm superior vena cava cannulation, and to improve the percentage of correctly placed CVCs and reduce complications of CVC placement. One hundred forty-five patients were studied. Eighty patients were randomized to have subclavian vein insertion, 64 to have internal jugular insertion, and 1 to have external jugular insertion of CVC. TEE-guided CVC placement resulted in 100% correct placement when assessed by preoperative TEE, versus 86% in the control group (72 of 72 vs 63 of 73; P = 0.01). There was no difference in correct placement between the two groups when assessed by postoperative chest radiograph (81.9% TEE versus 75.3% control; P = not significant). One significant complication, a superior vena cava perforation, occurred in the control group. Time to placement was 9.6 min in the TEE group versus 8.0 min in the control group (P = 0.015). Implications: Transesophageal echocardiography can be used to guide central venous catheter placement in congenital heart surgery. Central venous catheters that seem to be located high in the right atrium by chest radiograph in these patients are often actually in the superior vena cava and pose little risk of cardiac perforation.
UR - http://www.scopus.com/inward/record.url?scp=0033051551&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0033051551&partnerID=8YFLogxK
U2 - 10.1097/00000539-199907000-00012
DO - 10.1097/00000539-199907000-00012
M3 - Article
C2 - 10389780
AN - SCOPUS:0033051551
SN - 0003-2999
VL - 89
SP - 65
EP - 70
JO - Anesthesia and analgesia
JF - Anesthesia and analgesia
IS - 1
ER -