3D echocardiographic location of implantable device leads and mechanism of associated tricuspid regurgitation

Anuj Mediratta, Karima Addetia, Megan Yamat, Joshua D. Moss, Hemal M. Nayak, Martin C. Burke, Lynn Weinert, Francesco Maffessanti, Valluvan Jeevanandam, Victor Mor-Avi, Roberto M. Lang

Research output: Contribution to journalArticlepeer-review

102 Scopus citations

Abstract

Objectives This study sought to: 1) determine the feasibility of using 3-dimensional transthoracic echocardiography (3D TTE) in patients with implantable cardiac resynchronization devices, pacemakers, and defibrillators to visualize the device leads in the right heart and their position relative to the tricuspid valve leaflets; 2) determine the prevalence of different lead positions; and 3) study the relationship between lead location and tricuspid regurgitation (TR) severity. Background Pacemaker, defibrillator, and cardiac resynchronization device implantation is currently guided by fluoroscopy, not allowing targeted lead positioning relative to the tricuspid valve leaflets. These leads have been reported to cause TR of variable degrees, but echocardiography is not routinely used to elucidate the mechanisms of lead interference with tricuspid valve leaflets in individual patients. Methods 3D TTE full-volume images of the right ventricle and/or zoomed images of the tricuspid valve were obtained in 121 patients with implanted devices. Images were viewed offline to determine the position of the device-lead relative to the tricuspid valve leaflets. Severity of TR was estimated on the basis of vena contracta measurements. Results 3D TTE clearly depicted lead position in 90% of patients. The right ventricular lead was impinging on either the posterior (20%) or septal (23%) leaflet or was not interfering with leaflet motion (53%) when positioned near the posteroseptal commissure or in the central portion of the tricuspid valve orifice. In the remaining patients, leads were impinging on the anterior leaflet (4%) or positioned in either the anteroposterior or anteroseptal commissure (3%). Leads interfering with normal leaflet mobility were associated with more TR than nonimpinging leads (vena contracta: median 0.62 cm [1st and 3rd quartiles: 0.51, 0.84 cm] vs. 0.27 cm [1st and 3rd quartiles: 0.00, 0.48 cm]; p < 0.001). Conclusions 3D TTE showed a clear association between device lead position and TR. To minimize TR induced by device-leads, 3D TTE guidance should be considered for placement in a commissural position.

Original languageEnglish (US)
Pages (from-to)337-347
Number of pages11
JournalJACC: Cardiovascular Imaging
Volume7
Issue number4
DOIs
StatePublished - Apr 2014
Externally publishedYes

Keywords

  • 3-dimensional echocardiography
  • intracardiac defibrillator
  • pacemaker
  • tricuspid regurgitation
  • tricuspid valve

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of '3D echocardiographic location of implantable device leads and mechanism of associated tricuspid regurgitation'. Together they form a unique fingerprint.

Cite this